SPECIFICATIONS
Electrical
Input
Voltage
PTZ: 24 VAC @ 50/60Hz
Heater/Blower 24 VAC
@ 50/60Hz
Input Tolerance 24 VAC ± 20%
Power
Consumption
PTZ: 22 W @ 24 VAC
Heater/Blower 96 W
@ 24 VAC
Mechanical
Dimensions
Housing:
15.85"H x 12.29" Dia
Lower Dome: 9.50" Dia
Weight 15 lbs. (6.8 kg)
Construction
Top, inner: Steel
Top, outer: White
reflective acrylic
Bottom: Vacuum formed,
optically graded acrylic
Weather
Environmental
Operating
Temperature
-50°F to 122°F
(-45°C to 50°C)
(maintained by
heater/blower)
Regulations
Emissions
FCC: Part 15 Class A
CE: EN50081-1
Immunity CE: EN50082-1
Electrical
Input
Voltage
PTZ: 24 VAC @ 50/60Hz
Heater/Blower 24 VAC @ 50/60Hz
Input Tolerance 24 VAC ± 20%
Power
Consumption
PTZ: 22 W @ 24 VAC
Heater/Blower 96 W @ 24 VAC
Mechanical
Dimensions
Housing: 16.31"H x 12.41" Dia
Lower Dome: 9.50" Dia
Weight 17 lbs. (7.7 kg)
Construction
Top, inner: Steel
Top, outer: White reflective acrylic
Bottom: Vacuum formed, optically
graded acrylic
Sealing flange: 1/2" thick aluminum
casting with O-ring seals
Bottom dome: compresses O-rings
Interior
Pressurization
Dual Schraeder Valves for purging and
pressurisation. Single Over Pressure
valve – factory set @
7-10 lbs. Recommended: Dry nitrogen
gas for pressurisation only. Optional:
Recharge kit model AVN001NRK
Pressurised
Environmental
Operating
Temperature
-50°F to 122°F (-45°C to 50°C)
(maintained by heater/blower)
Regulations
Emissions
FCC: Part 15 Class A
CE: EN50081-1
Immunity CE: EN50082-1
Weather
Pressurised
Electrical
Input Voltage 24 VAC @ 50/60Hz
Input Tolerance 24 VAC ± 20%
Power Consumption 22 W @ 24 VAC
Mechanical
Dimensions
Housing: 7.25" H x 8.98" Dia
Lower Dome: 6.75" Dia
Trim Ring: 6.875" Dia
Weight 6.6 lbs.
Construction
Top, inner: Steel Bottom: Vacuum
formed, optically graded acrylic
Environmental
Operating
Temperature
32°F to 104°F
(0°C to 40°)
Regulations
Emissions
FCC: Part 15
Class A
CE: EN50081-1
Immunity CE: EN50082-1
Indoor Pendant