INSTALLATION INSTRUCTIONS
69- 157
6
E
F
® U.S. Re
g
istered Trademark
Co
py
ri
g
ht © 2001 Hone
y
well • All Ri
g
hts Reserved
69-1576EF G.H. 9-01 • www.hone
y
well.com/
y
ourhome
Home and Building Control Home and Building Control
Honeywell Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North 35 Dynamic Drive
Golden Valley, MN 55422 Scarborough, Ontario
M1V 4Z9
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer paper fibers.
HC18A, HC22A, HC26A
Humidifier Pad
APPLICATION
The HC18A, HC22A, and HC26A Humidifier Pads re
p
lace the
humidifier
p
ad in the Hone
y
well Flow-Throu
g
h Humidifiers or
A
p
rilaire® Humidifiers. The humidifier s
p
reads water over the
humidifier
p
ad, and when warm air blows over the water-
soaked area, va
p
or is
g
enerated. As the va
p
or circulates
throu
g
h the house, the relative humidit
y
rises.
INSTALLATION
CAUTION
Personal Injury or Equipment Hazard.
Can cause electrical shock or equipment damage.
Disconnect
p
ower su
pp
l
y
before installin
g
or servicin
g
.
Turn off water su
pp
l
y
.
IMPORTANT
Do not remove the powder from the new humidifier
pad. The powdery coating on the pad promotes
water dispersement.
1.
Remove the humidifier cover. See Fi
g
. 1.
2.
Remove the humidifier
p
ad assembl
y
from the humidi-
fier b
y
g
ras
p
in
g
the assembl
y
and
p
ullin
g
it toward
y
ou.
3.
Pr
y
o
p
en the frame at the corners until the PerfectFlo™
water distribution tra
y
lifts off.
4.
Gentl
y
p
inch the water nozzle catches inward until the
water nozzle can be lifted off the tra
y
.
5.
Slide the humidifier
p
ad out of the frame.
RECYCLE NOTICE
This humidifier
p
ad is rec
y
clable. After removin
g
the
p
ad from the humidifier, wash off the
p
owder and
rec
y
cle the
p
ad with the aluminum rec
y
clables.
IMPORTANT
Be careful not to punch the frame to prevent leaking.
6.
Carefull
y
scra
p
e an
y
mineral de
p
osits from the tra
y
and
frame. Be sure nothin
g
is blockin
g
the frame drain hole.
7.
Reattach the water nozzle to the PerfectFlo™ water dis-
tribution tra
y
.
8.
Insert the new humidifier
p
ad into the frame.
IMPORTANT
Be sure the black line on the top of the humidifier pad
is facing up.
9.
Re
p
lace the water distribution tra
y
. Be sure all four tabs
are in
p
lace.
10.
Place the humidifier
p
ad assembl
y
in the humidifier
housin
g
and
p
ress until the assembl
y
is com
p
letel
y
sealed. Be careful not to
p
inch or kink the water feed
tube.
Fig. 1. Humidifier components.
11.
Re
p
lace the humidifier cover.
12.
Turn on the
p
ower and water su
pp
l
y
.
13.
To verif
y
the humidifier o
p
eration, refer to the Owner’s
Guide Checkout Procedure section.
M12371A
PerfectFlo“ WATER DISTRIBUTION TRAY
WATER FEED NOZZLE
HUMIDIFIER PAD
HUMIDIFIER
HOUSING
COVER
FRAME
WATER
FEED
TUBE