Honeywell F50E Air Cleaner User Manual


 
F50E DUCT MOUNTED ELECTRONIC AIR CLEANER
68-0072—5
21
P3
P4
P1
P2
P17
P18
2
1
P14
P5
P12
3
P21
4
BLACK
1
2
3
4
1
2
3
4
TERMINAL STRIP
FRONT BACK
TO
W8600E
WALL
PANEL
W4 W2 W1 W3
AIRFLOW SWITCH BOARD
ORANGE
GRAY
VIOLET
BLACK
1 INTERLOCK SWITCH.
2 OUTPUT REDUCTION JUMPER.
3 AIRFLOW SWITCH DISABLE JUMPER.
4 RESISTOR FOR W8600 WASH INDICATION THRESHOLD.
5 P1, P2 TERMINALS ON 120V MODELS ONLY. POWER CONNECTIONS ON 240V MODELS ARE TO QUICK-CONNECTS ON POWER
SUPPLY TRANSFORMER. BROWN LEAD GOES TO TOP TERMINAL AND BLACK LEAD TO BOTTOM TERMINAL.
M4702
POWER
SUPPLY
2
BLACK
RED
TEST
BUTTON
CONTACT
BOARD
RED IONIZER
BLACK COLLECTOR
BLACK
J2
5
4
R43
BLACK
BLACK
BROWN
BLACK
BLACK
WHITE
GREEN
3
1
GREEN
J7
INTERNAL SCHEMATIC FOR ELECTRONIC AIR CLEANER WITH W8600E.
The solid state power supply provided in this air cleaner has
no field-serviceable components. If troubleshooting indicates
a power supply problem, replace the entire power supply. See
Parts List section for order number.
To Access Power Supply
1. Turn off power.
2. Remove the access door and loosen the two screws
holding the power box. See Fig. 32.
3. To pull the plug connector out of the receptacle in the
junction box, lift slightly to clear screws, then pull the
power box straight toward you.
4. Take out the two screws holding on the cover. Remove
the cover.
5. Replace the power box by resting it on the cabinet,
lifting slightly to clear two screws, and pushing it
straight toward the junction box. Do not bend the spring
contacts sideways. The power plug must slide straight
into the receptacle.
6. Replace the access door and restore power.