Honeywell F300 Air Cleaner User Manual


 
F300 ELECTRONIC AIR CLEANER
68-0240EF-5 2
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
SPECIFICATIONS
IMPORTANT
The specifications given in this publication do not
include normal manufacturing tolerances. Therefore,
this unit may not exactly match the listed specifica-
tions. This product is tested and calibrated under
closely controlled conditions, and some minor differ-
ences in performance can be expected if those con-
ditions are changed.
Model:
F300E Electronic Air Cleaner: Includes cabinet, access door,
solid state power supply, two electronic cells, two metal
mesh prefilters, and two media postfilters.
F300A,B Electronic Air Cleaner: Includes cabinet, access
door, solid state power supply, two electronic cells and two
metal mesh prefilters.
Electrical Ratings:
Voltage and Frequency: Models available for 120V, 60 Hz.,
240V, 60Hz. 120V models can be converted in the field to
240V, 60 Hz or 220/240V, 50 Hz with the 203365A
Conversion Kit.
Power Consumption:
One cell models: 22 W maximum
Two cell models: 36 W maximum.
Current Draw: See Table 1.
Ionizer Voltage: 8150 Vdc.
Collector Voltage: 4075 Vdc.
Fractional Efficiency:
Efficiency ratings are based on American Society of Heating,
Refrigerating and Air-Conditioning Engineers Standard
52.2-1999. Efficiency ranges are defined for small particles,
E
1
=.3 to 1.0 micron; medium particles, E
2
= 1.0 to 3.0
microns; and large particles, E
3
= 3.0 to 10.0 microns.
Table 1. Current Draw.
Size
No.
Cells
Max Current (A)
in. mm 120V 220/240V
16 x 25 406 x 635 2 0.4 0.2
20 x 25 508 x 635 2 0.4 0.2
16 x 20 406 x 508 2 0.4 0.2
20 x 20 508 x 508 2 0.4 0.2
20 x
12-1/2 508 x 318 1 0.4 0.2
Table 2. Fractional Efficiency With and Without Postfilter.
With postfilter Without postfilter
E
1
= Up to 81% at 492 fpm. E
1
= Up to 73% at 492 fpm.
E
2
= Up to 93% at 492 fpm. E
2
= Up to 88% at 492 fpm.
E
3
= Up to 99% at 492 fpm. E
3
= Up to 95% at 492 fpm.