STEP 5. SET HEAT ANTICIPATOR
ON NEW THERMOSTAT
1. Set the heat anticipator lever to the number that
you recorded in Step 2. Remove Old Thermostat,
sub-step 4 (see Fig. 7).
Fig. 7. Heat anticipator on new thermostat.
2. If you could not find a heat anticipator setting on
your old thermostat, use the setting listed in
Table 1 for your type of heating system.
Table 1. Heat Anticipator Setting.
3.
Place the cover on the thermostat and turn the
power back on. If the heating system runs too long
to maintain a comfortable temperature, adjust heat
anticipator lever clockwise one scale mark (see Fig.
7). Do not adjust heat ancitipator below .3 Amps. If
the heating system needs to run longer to maintain
a comfortable temperature, adjust heat anticipator
lever counterclockwise, in the direction of the arrow,
one scale mark (see Fig. 7).
STEP 6. OPERATING NEW
THERMOSTAT
1. Adjust the temperature setting lever to your desired
setting. If it is too warm, lower the temperature set-
ting. If it is too cool, raise the temperature setting.
IF YOU HAVE A PROBLEM
Customer Assistance
Please read and follow the provided instructions for this
thermostat. For additional information, go to
www.honeywell.com/your home
or call Honeywell
Customer Care at 1-800-468-1502.
Before calling, please have the following information
available:
Thermostat model number and date code (refer to Fig.
6 for the location of the model number and date code).
Type of heating system (for example: gas or oil; warm
air, hot water).
Heating System
Heat Anticipator
Setting (Amps)
Hot Water .8
High Efficiency Warm Air (90% or
better)
.8
Gas or Oil Warm Air .4
Electric .3
.18
.2
.25
.3
.9
.7
.5
.4
L
O
N
G
E
R
M19650
PLACE FINGER
HERE TO MOVE
LEVER
HEAT ANTICIPATOR
.18
.2
.25
.3
.9
.7
.5
.4
L
O
N
G
E
R
DATE CODE
MODEL NO.
THIS POINT
SHOULD ALIGN WIT
H
HEAT ANTICIPATOR
SETTING
If. . . Then. . .
Heating system
does not come on.
Make sure the temperature
setting is above the room
temperature.
Make sure the circuit breaker
is not tripped and reset it if
necessary.
Make sure the power switch at
the equipment is in the On
position.
Wait 5 minutes for the system
to respond.
Heating system runs
too long to maintain
a comfortable
temperature.
Verify the thermostat is level.
Adjust heat anticipator lever
clockwise one scale mark (see
Fig. 7). Do not adjust heat
anticipator below .3 Amps.
Heating system
needs to run longer
to maintain a
comfortable
temperature.
Verify the thermostat is level.
Adjust heat anticipator lever
counterclockwise, in the
direction of the arrow, one
scale mark (see Fig. 7).