Honeywell CT2095 Thermostat User Manual


 
29 69-1385
Cooling
To avoid possible compressor damage, do not
operate the cooling system when outdoor
temperature is below 50°F (10°C). See
compressor manufacturer instructions.
IMPORTANT
When cooling setting is changed, ther-
mostat delays up to five minutes
before turning on the air conditioner.
This delay protects the compressor.
Move the System switch to
Cool and the Fan switch to
Auto.
Press TEMP key until setting is
about 10°F (6°C) below room
temperature. The cooling
equipment and fan should start.
Press TEMP key until the setting is about 10°F
(6°C) above room temperature. The cooling
equipment and fan should stop.
Move the System switch to Off;
keep the Fan switch at Auto.
The system and fan should be
off.
TEMP
HeatCool Off
M1704
Auto On
M1705
HeatCool Off
M1707
Auto On