Honeywell CM921 Thermostat User Manual


 

The Built-in Heating Program
The built-in heating program has 6 temperature level changes that can be set
between 3.00am and 2.50am - allowing you to maintain the evening temperature
after midnight. Each temperature level can be set between 5°C and 35°C, and
adjusted in 0.5°C increments. The factory default program for heating is as follows:
Reviewing the Heating Program
To review or edit the heating program move the slider switch to the PROG position
then use the
or buttons to navigate between the 6 individual programming
periods.
Modifying the Heating Program
To change the heating program:
a. Set the slider switch to the PROG position, entering programming mode. ‘SET
TIME 1’ will be displayed and the time settings for period
1
will be flashing. The
active period is highlighted by a flashing square symbol around the numbers at
the bottom of the screen.
Period 1 2 3 4 5 6
Time 6:30 8:00 12:00 14:00 18:00 22:30
Temperature 21°C 18°C 21°C 18°C 21°C 16°C
DATE
PROG
AUTO
MAN
OFF
1 65432