Honeywell C8600A Carbon Monoxide Alarm User Manual


 
69-1513EF—01 10
LOCATIONS TO AVOID
Near an open window or door with fresh air
entering the opening and delaying the CO
from reaching the alarm.
In damp or very humid areas or next to
bathrooms with showers; install detectors at
least 10 ft (3 meters) away from bathrooms.
In very cold or very hot environments or in
unheated buildings or outdoor rooms where
the temperature can drop below or rise
above the operating range of the alarm;
temperature limits for correct operation are
40° to 100°F (5° to 38°C).
In areas where nuisance alarms can result
because CO alarms are placed where they
cannot operate correctly such as:
Within 5 ft (1.5M) of any cooking appli-
ance or furnace.
In areas of limited ventilation where
household cleaning supplies or similar
contaminants are used.
CONDITIONS THAT CAN RESULT IN TEMPORARY CO
SITUATION
Excessive spillage or reverse-venting of
fuel-burning appliances from outdoor
ambient conditions such as:
Wind direction and/or velocity, including
high gusts of wind; heavy air in vent
pipes (cold /humid air with extended
periods between cycles).
Negative pressure differential resulting
from using exhaust fans.
Simultaneous operation of several fuel-
burning appliances that compete for lim-
ited internal air.