ÊK0022V36Š
K0022V3 3/09 Rev. A
SETTING THE KEYPAD OPTIONS
The procedures that follow are used to set the keypad
address, voice chime mode, and additional voice keypad
mode.
Setting The Keypad Address
When used with the VISTA-15P/VISTA-20P
control panels, address 16 must be assigned to
the first Keypad. Additional Keypads must be
set at 17 - 23 and must be enabled additionally
in control programming (fields *190 - *196).
The keypad can either be set for an address of 00-30 or for
non-addressable mode (31). The default keypad address is
31. For valid address settings for your keypad, refer to the
control panel's Installation & Setup Guide.
Note:
• If unable to enter the address mode, power down,
power up, and try again.
• If 10 seconds pass with no key entry, the keypad
automatically exits the address mode. You must
power down, power up, and start the address mode
again.
• The keypad will not enter the address mode if the
control panel is in programming mode.
1. Apply power to the keypad.
2. Within 60 seconds of applying power to the keypad, press
and hold down the [1] key and [3] key at the same time
for 3 seconds. The current keypad address will be
displayed.
3. Press "00".
The current address is cleared.
4. Enter desired keypad address.
5. Press [*] to save the displayed address and enter the
Voice Chime mode. "VOICE CHIME" (alpha keypad) or
"C" (fixed keypad) is displayed along with the selected
mode "1" or "0".
Setting The Voice Chime Mode
6. Press [1] to set the Voice Chime mode on or press [0] to
set the Voice Chime mode off.
7. Press [*] to save the displayed Voice Chime mode and
enter the Additional Console voice keypad mode.
"ADDITIONAL CON" (alpha keypad) or "A" (fixed
keypad) is displayed along with the selected mode "1" or
"0".
Note: Setting Voice Chime mode off does not effect the
voice status or alarm annunciation.
Setting The Additional Console Mode
The Additional Console mode must be set for all voice
keypads being used.
8. Set the voice keypad Additional Console mode as
follows:
a. On the Primary voice keypad, press [0] to set the
Additional Console mode to NO.
b. On any secondary voice keypads, press [1] to set
Additional Console mode to YES.
9. Press [*] to save the mode.
VIEWING THE KEYPAD ADDRESS
Press and hold down the [1] key and [3] key at the same
time for about 3 seconds. The current address is displayed.
No key entry is allowed. Press any key to exit or wait 10
seconds to exit the viewing mode.
OPERATING THE KEYPAD
For operating instructions, see the User Guide for the
control panel used with this keypad.
SPECIFICATIONS
Physical:
6150V: 4-7/8"H x 6-1/4"W x 1"D
6160V: 5-5/16"H x 7-3/8"W x 1-3/16"D
Displays:
6150V: Fixed-Word LCD (backlit)
6160V: 2 x 16 Alpha-Numeric Super twist LCD
(backlit)
Sounder: Speaker
Electrical:
Voltage: +12VDC (power-limited)
Current:
6150V: 160mA (ARMED LED lit, LCD backlight and
sounder on) reduces to 60mA when panel is
operating in standby mode (backlight off).
6160V: 190mA (ARMED LED lit, LCD backlight and
sounder on) reduces to 60mA when panel is
operating in standby mode (backlight off).
NFPA72 Compliant.
TABLE 1. ZONE DESCRIPTORS AND INDEX ENTRIES
ALARM 002
DOOR
057
KITCHEN
105 PATIO 146
UPSTAIRS
207
ATTIC 009
EMERGENCY
067
LAUNDRY
106
POLICE
151
UTILITY
208
BABY 012
EXIT
071
LIBRARY
109
POOL
152
WINDOW
217
BACK 013
FIRE
079
LIVING
113
ROOM
162
YARD
223
BASEMENT 016
FLOOR
080
MAIN
122
SHED
168
ZONE
225
BATHROOM 017
FRONT
085
MASTER
123
SHOP
170
1ST
228
BEDROOM 019
GARAGE
089
MEDICAL
125
SIDE
173
2ND
230
CLOSED
040
GUN
094
MOTION
131
SLIDING
175
3RD
232
DEN
050
HALL
095 OFFICE 136
SMOKE
176
DETECTOR
052
HOUSE
099 OPEN 138
STORAGE
185
DINING
053
INSIDE
101 PANIC 144
SUPERVISED
190
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR
WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
For the latest warranty information, please go to:
http://www.security.honeywell.com/hsc/resources/wa/index.html
2 Corporate Center Drive, Suite 100, P.O. Box 9040, Melville, NY 11747
Copyright
2009 Honeywell International Inc.
www.security.honeywell.com