Honeywell 5800ZBRIDGE Home Security System User Manual


 
800-08932 5/11 Rev. A
- 1 -
5800ZBRIDGE
Z-Bridge Module
INSTALLATION AND SETUP GUIDE
GENERAL INFORMATION
5800ZBRIDGE is a wireless, intelligent energy
management device that provides an interface
between Z-Wave Modules and Honeywell LYNX
Security Systems and VISTA Control Panels that are
equipped with RF keypads.
Note: The 5800ZBridge is not compatible with the 5800TM or
5883H modules.
Features
Automatically set back Z-Wave enabled
thermostat when security system is Armed
AWAY.
Automatically turns lights off when security
system is Armed AWAY.
Sends run command to Z-Wave enabled
thermostat when security system is Disarmed.
Automatically turns lights on when security
system is Disarmed.
Alarm Status light: Ready, Armed Away and Stay.
Will function with any Z-Wave device
MOUNTING
1. Determine the optimum mounting location taking
care to avoid damp locations. To maximize the
transmitter’s range, avoid mounting the device to
metal objects, if possible. The module should be
located a maximum of 6 feet from an unswitched
120VAC outlet.
2. Open the 5800ZBRIDGE case as shown in Figure
1.
3. Mount the 5800ZBRIDGE using the provided
screws. (Refer to Figure 2)
5800Z-002-V0
Figure 1. Opening the 5800ZBRIDGE
POWER UP MODULE
1. Plug in 12VDC power supply, LED flashes
ORANGE 3 times and then goes out. (Refer to
Figure 2)
PROGRAMMING
Enroll 5800TM Code into Module
1. Press SW5 LEARN switch for 1 second and
release. LED will begin flashing ORANGE.
2. Disarm or Arm the control panel (with 5800TM
code turned on). The LED will stop flashing
ORANGE and the color will follow status of the
control panel.
Note: The module will time out of program mode after 3
minutes if no TM code is enrolled.
Table 1 - 5800ZBRIDGE LED Indications
Indication Meaning
Flashing Red Armed AWAY
Steady Red Armed STAY
Solid Green Ready
Flashing Orange ALARM/Panic
Note: Following an alarm, the User Code must be entered
twice and the keypad must go to ready in order for the
Z-Bridge Module to release thermostat setback and/or
turn on lights.
Enroll (include) Devices in Z-Wave Modules into
5800ZBRIDGE module
1. Press the corresponding switch (SW1 through 4)
for 1 second and release for any combination of
four Thermostats or Lights. (Refer to Figure 2)
2. The 5800ZBRIDGE LED will begin flashing
Green.
3. Press button on the respective Z-Wave device to
learn (include) the device. The 5800ZBRIDGE
LED will stop flashing GREEN and return to
status of control panel.
4. Repeat for each Z-Wave device as applicable.
Note: The module will time out of program mode after 2
minutes if no Z-Wave device in enrolled (included).
Reset 5800ZBRIDGE Module
1. Disconnect the 12VDC power supply.
2. Press and hold SW5 LEARN switch and then plug
in 12VDC power supply. LED flashes Orange 5
times and then goes out.
3. Release switch SW5. TM code has been deleted
and 5800ZBRIDGE has been deleted (excluded)
from the Z-Wave network.