Honeywell 5000 Series Thermostat User Manual


 
2 3 4 5
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Toronto, Ontario M1V 4Z9
http://yourhome.honeywell.com
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer paper fibers.
® U.S. Registered Trademark
© 2006 Honeywell International Inc.
US Patent No. 6595430, D509151; other
Patents Pending. All Rights Reserved
69-2026 M.S. 09-06
INSTALLER SETUP
To begin, press and hold the s and FAN buttons until
the display changes.
Press s or t to change settings.
Press NEXT to advance to the next function.
Press DONE to exit and save settings.
Proceed to Installer Setup Functions on page 4.
1.
2.
3.
4.
5.
To begin, press and hold the s and FAN buttons until
the display changes.
Press s or t to change settings.
Press NEXT to advance to the next function.
Press DONE to exit and save settings.
Proceed to Installer Setup Functions on page 4.
1.
2.
3.
4.
5.
INSTALLER SETUP FUNCTIONS
Available option and default settings vary by thermostat.
Table 1. Installer Setup
Setup functions Setting & Options
(factory default in bold)
1 System type 0 1 heat / 1 cool Conv.
1 1 heat / 1 cool heat
pump (no Aux. heat)
2 Heat only (2-wire, 3-wire
zone valves [Series 20],
and normally open zone
valves)
3 Heat only with fan
4 Cool only
5 2 heat / 1 cool heat
pump (with Aux. heat)
6 2 heat / 2 cool Conv.
7 2 heat / 1 cool Conv.
8 1 heat / 2 cool Conv.
9 2 heat / 2 cool heat pump
(no Aux. heat)
10 3 heat / 2 cool heat
pump (with Aux. heat)
2 Changeover valve
(O/B terminal)
0 Controls valve in cooling
1 Controls valve in heating
3 Fan control
(heating)
0 Gas/Oil heat (equipment
controls heating fan)
1 Electric furnace (thermo-
stat controls heating fan)
5 First stage heat
cycle rate
5 Gas or oil furnaces of
less than 90%
efciency
1 Steam or gravity
3 Hot water systems or fur-
naces of 90%+ efciency
9 Electric furnaces
[Other options: 1–12]
6 Second stage
heat/Aux heat
cycle rate
5 Gas or oil furnaces of
less than 90% efciency
1 Steam or gravity
3 Hot water systems or fur-
naces of 90%+ efciency
9 Electric furnaces
[Other options: 1–12]
7 Auxiliary heat
cycle rate
5 Gas or oil furnaces of
less than 90% efciency
1 Steam or gravity
3 Hot water systems or fur-
naces of 90%+ efciency
9 Electric furnaces
[Other options: 1–12]
Table 1. Installer Setup
Setup functions Setting & Options
(factory default in bold)
8 Emergency heat
cycle rate
9 Electric emergency heat
1 Steam or gravity
3 Hot water systems or fur-
naces of 90%+ efciency
5 Gas or oil furnaces of
less than 90% efciency
[Other options: 1–12]
9 First stage
compressor cycle
rate
3 Recommended
[Other options: 1–6]
10 Second stage
compressor cycle
rate
3 Recommended
[Other options: 1–6]
12 Manual/Auto
changeover
0 Manual changeover
(Heat/Cool/Off)
1 Auto changeover (Heat/
Cool/Auto/Off)
2 Auto changeover only
(Auto)
13 Adaptive Intel-
ligent Recovery
TM
1 On
0 Off
14 Temperature
display
0 Fahrenheit
1 Celsius
15 Compressor
protection
5 5-minute compressor
off time
[Other options: 0–4
minutes]
16 Schedule format 0 5/2 (weekdays
and weekends
programmable)
1 5/1/1 (weekdays,
Saturday, and Sunday
programmable)
26 Auxiliary heat
control
0 Comfort
1 Economy
27 Heat temperature
range stops
90 Max. heat temperature
setting is 90°F (32°C)
[Other options: 40–89°F
(4.5°C to 32°C)]
28 Cool temperature
range stop
50 Min. cool temperature
setting is 50°F (10°C)
[Other options: 51–99°F
(10.5°C to 37°C)]
Functions 13 and 16 only available on the 6000 series;
function 26 only available on the 5000 series
1
0
Done Next
1
0
Done
Next
Function Setting
FocusPRO
®
6000 Series
Function Setting
FocusPRO
®
5000 Series