Honeywell 2000B Indoor Furnishings User Manual


 
FlashGuard 2000B Troubleshooting Guide
Page 11
Status Indicators
Control Power ON
Located on the control panel (top center), this indicator is illuminated whenever input
power is present and the power supply interlock switch is engaged.
High Voltage Neon Lamp
Located on the high voltage circuit (top) board, this lamp indicates that the high
voltage circuits are active.
Extreme caution should be used if the neon lamp is on.
Flashhead Alarm Status LED
Located on the sync/monitor (middle) board, this LED will be green when the
flashhead is operating correctly.
If the LED is off, the system is in alarm mode.
Sync Out LED
Located on the sync/monitor (middle) board, this LED blinks red to indicate that a
sync signal has been generated.
In a multiple flashhead system, only the sync/monitor board that is set as the master
will blink this LED.
Sync In LED
Located on the trigger/control (bottom) board, this LED blinks green to indicate that a
sync signal has been received from the sync/monitor board.
Tools Required
Flat head screwdriver
5/16” nutdriver to open flashhead
Clean gloves to use when changing flashtubes
Digital multimeter w/ Ohm reading and 500 VDC capacity
NE2 neon light, Radio Shack catalog number 272-1102, Honeywell part # 77-2342
Short piece of wire for jumper (Approx. #12 wire gauge)