Homelite HP275 Electric Heater User Manual


 
4
099238
LP-PFA/PV 013ALP 275
Main Burner
Valve Handle
Main Burner
Valve
PRODUCT
IDENTIFICATION
1. Remove all packing items applied to heater for shipment. Keep plastic cover
caps (attached to inlet connector and hose/regulator assembly) for storage.
2. Remove all items from carton.
3. Check all items for shipping damage. If heater is damaged, promptly inform
dealer where you bought heater.
UNPACKING
Figure 1 - HP275
Pilot
Inlet
Connector
Hose/Regulator
Assembly
Note: Debris Shield
Not Shown
THEORY OF
OPERATION
The Fuel System: The hose/regulator assembly attaches to the propane gas
supply. This provides fuel to the heater.
The Ignition System: The piezo ignitor lights the pilot fuel supply.
The Automatic Control System: The automatic control valve shuts off the
heater if the flame goes out.
Automatic
Control Valve
Button
Ignitor
Electrode
Thermocouple
Piezo Ignitor
Button
Base
Automatic
Control Valve
Shell
Top