3. Connect hose to inlet connector. Tighten firmly using a wrench.
IMPORTANT:
Extra hose or piping may be used if needed. Install extra hose
or piping between hose/regulator assembly and propane tank. You must use
the regulator supplied with heater.
4. Open propane supply valve on propane tank(s) slowly.
Note:
If not opened
slowly, excess-flow check valve on propane tank may stop gas flow. If this
happens, close propane supply valve and open again slowly.
5. Check all connections for leaks.
Figure 4 - Hose and Inlet Connector
Generic LP 155
LP-PFA/P 022B
Hose
Inlet Connector
VENTILATION
!
WARNING
Follow the minimum fresh, outside air ventilation require-
ments. If proper fresh, outside air ventilation is not provided,
carbon monoxide poisoning can occur. Provide proper fresh,
outside air ventilation before running heater.
Provide a fresh air opening of at least four and one half (4.5) square feet. Provide
extra fresh air if more heaters are being used.
Example:
A 150,000 BTU/Hr heater requires one of the following:
a two-car garage door raised six inches
a single-car garage door raised nine inches
two thirty-inch windows raised twelve inches
!
WARNING
Never use an open flame to check for a leak. Apply a mixture
of liquid soap and water to all joints. Bubbles forming show a
leak. Correct all leaks at once.
6. Close propane supply valve.