Holmes HM5082 Humidifier User Manual


 
P L E A S E R E A D A N D S AV E T H E S E
I M P O R TA N T S A F E T Y I N S T R U C T I O N S
Never use detergents, gasoline, kerosene, glass cleaner,
furniture polish, paint thinner or other household solvents
to clean any part of the humidifier.
WEEKLY MAINTENANCE
Remove scale:
1. Repeat steps 1-3 in the Daily Maintenance section.
2. Clean the tray by partially filling the tray with one 8-
oz cup of undiluted white vinegar. Let solution stand
20 minutes, cleaning all interior surfaces with a soft
brush. Dampen a cloth with undiluted white vinegar
and wipe out entire tray to remove scale.
3. Rinse with clean warm water to remove scale and the
white vinegar solution before beginning to disinfect
the tank.
4. Wipe the heating element clean with a soft cloth after
it has had a chance to cool.
Disinfect tank:
1. Fill tank with 1/2 teaspoon of chlorine bleach and
1/2 gallon of water.
2. Let the solution stand for 20 minutes, swishing every
few minutes. Wet all surfaces.
3. Empty the tank after 20 minutes, and rinse well with
water until the bleach smell is gone. Dry with a clean
cloth or paper towel.
4. Refill the water tank with cool water; replace the
housing and the water tank. Repeat ALL Operating
Instructions.
STORAGE INSTRUCTIONS
If your humidifier will not be in use for two days or more,
or at the end of the season follow these instructions.
1. Clean, rinse and thoroughly dry the humidifier as
directed in the weekly maintenance section. DO NOT
leave any water inside the base or tray.
2. Wait for the heating element to cool completely, and
then clean the heating element with a damp soft
cloth.
3. Remove the tank cap. Do not store with the tank cap
in place.
4. Place the humidifier in the original carton and store
in a cool, dry place.
5. Always clean the humidifier before the next season
begins.
F E AT U R E S - O P E R AT I O N S
I M P O R TA N T S A F E T Y I N S T R U C T I O N S
W E E K LY M A I N T E N A N C E
S T O R A G E I N S T R U C T I O N S
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire,
electric shock, and injury to persons, including the
following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance
directly into a 120V AC electrical outlet.
3. Keep the cord out of heavy traffic areas. To avoid fire
hazard, NEVER put the cord under rugs or near heat
registers.
4. DO NOT place humidifier near heat sources such as
stoves, radiators, and heaters. DO locate your
humidifier on an inside wall near an electrical outlet.
The humidifier should be at least 4 inches (10 cm)
away from the wall for best results.
5. NEVER place humidifier in an area where it is
accessible to children. NEVER use humidifier in a
closed room, particularly where a child may be
sleeping, resting, or playing (a closed room may
result in excessive humidity).
6. WARNING: Do not attempt to refill humidifier
without first unplugging the unit from its electrical
outlet. Failure to heed this warning may cause
personal injury. Be sure to unplug the unit by pulling
on the plug and not the cord.
7. Never place anything over moisture outlet when the
unit is running.
8. NEVER drop or insert any object into any openings
unless instructed in this manual.
9. DO NOT operate any appliance with a damaged cord
or plug, after the appliance malfunctions, or if it has
been dropped or damaged in any manner. Return
appliance to manufacturer for examination, electrical
or mechanical adjustment, or repair.
10. Use appliance only for intended household use as
described in this manual. Any other use not
recommended by the manufacturer may cause fire,
electric shock, or injury to persons. The use of
attachments not recommended or sold by the
manufacturer may cause hazards.
11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level surface.
A waterproof mat or pad is recommended for use
under the humidifier. NEVER place it on a rug or
carpet, or on a finished floor that may be damaged
by exposure to water or moisture.
13. DO NOT allow the Moisture Outlet to directly face the
wall. Moisture could cause damage, particularly to
wall paper.
14. Humidifier should be unplugged when not in use.
15. NEVER tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water tank and moving the unit.
16. This humidifier requires daily and weekly
maintenance to operate appropriately. Refer to daily
and weekly cleaning procedures. Use only cleaners
and additives recommended by the manufacturer.
17. NEVER use detergents, gasoline, glass cleaner,
furniture polish, paint thinner, or other household
solvents to clean any part of the humidifier.
18. Excessive humidity in a room can cause water
condensation on windows and some furniture. If this
happens, turn the humidifier OFF.
19. Do not use humidifier in an area where humidity
level is in excess of 50%. Use a hygrometer,
available at your local retailer or through the
manufacturer, to measure the humidity.
20. DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
your warranty. The inside of the unit contains no user
serviceable parts. All servicing should be performed
by qualified personnel only.
21. Never place housing under water flow or immerse in
liquids.
22. Do not plug in the cord with wet hands: electric shock
could result.
23. Do not pour water in any openings other than the
water tank.
24. To prevent damage to surfaces, do not place
humidifier under overhanging surfaces.
25. NEVER operate unit without water in the tank.
26. Do not move unit after it has been used until unit
cools completely.
27. Use both hands when carrying full tank of water.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
Consumer Safety Information
Note: This is an electrical appliance and requires attention
when in use.
Note: If moisture forms on the walls or windows of the
room, turn off the humidifier. The room already has plenty
of humidity and additional moisture may cause damage.
Cord and Plug Installation Safety
Instructions
The length of cord used on this appliance was selected to
reduce the hazards of becoming tangled in, or tripping
over a longer cord. If a longer cord is necessary an
approved extension cord may be used. The electrical
rating of the extension cord must be equal to or greater
than the rating of the humidifier (refer to the rating
artwork placed on the humidifier). Care must be taken
to arrange the extension cord so that it will not drape
over the countertop or tabletop where it can be pulled on
by children or accidentally tripped over.
HOW WARM MIST WORKS
Your Holmes
®
Warm Mist humidifier is designed to allow
the proper amount of water to flow out of the tank. Air is
drawn in through the grill openings located in the back of
the unit and mixed with steam in the misting chamber. The
warm mist is then dispersed out of the top of the misting
chamber through the outlet grill and into the room.
NOTE: A humidity level below 20% can be unhealthy and
uncomfortable. The recommended humidity level is
between 40%-50%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched off.
2. Select a location for your humidifier, on a flat level surface
about 4 inches (10 cm) away from the wall. DO NOT place
the humidifier on a finished floor or near furniture, which
can be damaged by too much moisture or water. Place on
a moisture resistant surface.
3. Remove the tank from the main housing.
4. Bring the tank to the sink, turn upside down and twist
off the tank cap by turning counter clockwise. Fill tank
with cool, fresh tap water. DO NOT fill with warm
water as this may cause leaking. Replace the cap on
tank FIRMLY. The tank will hold 1.3 gallon of water.
The humidifier will produce up to 2.5 gallons of water
over a 24 hour time period.
5. Make sure the safety lock is rotated completely to the
locked position. Place tank back on to the base. The
tank will immediately begin to empty into the base.
6. Plug the humidifier into a 120V electrical outlet.
OPERATING INSTRUCTIONS
1. Fill the water tank.
2. Turn the power knob to the HIGH position. The power
light will be ON and the Reset Light will be off. It is
normal for the humidifier to take about 10 minutes
to warm up and begin to mist.
3. After the unit begins misting, set the humidifier to
the desired power setting (HIGH or LOW).
RESET PROCEDURE
NOTE: When the water tank is empty and the water in
the Heating Chamber is almost empty, the Automatic Shut
off will activate. The RESET Light will illuminate and the
unit will not operate again until you refill the water tank
and reset the humidifier.
1. Turn the power knob to RESET.
2. Unplug the unit.
3. Remove and refill the water tank, being sure to
follow the Daily Maintenance Instructions. Replace
the tank onto the base.
4. Wait 15 minutes for the Automatic Shut-Off to reset.
5. After the 15 minutes, plug in the unit and turn the
Power Knob, to HIGH. The RESET light should now be
off (if not repeat steps 1-5). In about 10 minutes, the
humidifier will begin to produce moisture.
If the reset light is still on at this point, and the unit does
not begin to produce moisture within a few minutes, then
repeat Steps 1-5.
IMPORTANT: If you do not plan to use the humidifier
for two or more days, make sure any residual water is
drained from the water tank and base to prevent algae
or bacteria growth.
CLEANING AND MAINTENANCE
INSTRUCTIONS
The following maintenance procedures must be
routinely followed in order to ensure proper,
efficient operation of your humidifier. The unit
will not work properly if not cleaned regularly.
When the unit is in use, daily and weekly maintenance is
recommended. Regular weekly cleaning prevents scale
buildup on the heating element and tray. It also prevents
micro-organisms from growing on the tray and tank. This
ensures that maximum efficiency will be achieved.
We cannot over-emphasize how essential proper
cleaning is to the maintenance and continued use
of your unit and to the avoidance of algae or
bacteria build-up.
DAILY MAINTENANCE
1. Before cleaning, set the power knob to OFF position
and unplug the unit from the electrical outlet.
2. Remove the water tank then unlock the misting
chamber by rotating the safety lock towards the back
of the unit. Lift mist chamber from the unit’s base.
Now lift the tray from the base.
3. Empty water and minerals from the tray and place in
the top rack of the dishwasher. This will remove any
sediment and dirt that has accumulated in the tray.
NOTE: It is imperative that the tray is cleaned properly.
The tray is dishwasher safe (top rack ONLY) for easy
cleaning.
4. Wipe the heating element clean with a soft cloth after
it has had a chance to cool.
The Electronic Thermal Control Heating element is lined
with a coating that is designed to provide the easiest
cleaning and prolong the operating efficiency of the
humidifier. DO NOT use any metal or hard objects to
clean the Heating Element.
F E AT U R E S - O P E R AT I O N S
CLEANING/MAINTENANCE
Reset
Off
Low
High
Reset
Off
Low
High
Figure 1
A
B
C
D
E
F
G
H
A. Carry Handle
B. Humidifier Tank
C. Humidifier Base
D. Removable Tray
E. Heating Element
F. 2-Speed Humidity
Control/Power Knob
G. Humidifier Housing
H. Vent
THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended to fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to
install the proper outlet.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS
SAFETY FEATURE IN ANY WAY.
HM5082-U_08EM1.qxd:9100030005027 5/5/08 3:49 PM Page 2