When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance
directly into a 120 V AC electrical outlet.
3. Keep the cord out of heavy traffic areas. To avoid
fire hazard, NEVER put the cord under rugs, near
heat registers, radiator, stoves, or heaters.
4. DO NOT place humidifier near heat sources such as
stoves, radiators, and heaters. Do locate your humidifier
on an inside wall near an electrical outlet. The humidifier
should be at least 4" away from the wall for best results.
5. NEVER place humidifier in an area where it is accessible
to children. NEVER use humidifier in a closed room,
particularly where a child may be sleeping, resting, or
playing (a closed room may result in excessive humidity).
6. WARNING: Do not attempt to refill humidifier without first
unplugging the unit from it’s electrical outlet. Failure to
heed this warning may cause personal injury. Be sure to
pull the plug and not the cord.
7. Never place anything over moisture outlet when
the unit is running.
8. NEVER drop or insert any object into any openings.
9. DO NOT operate any appliance with a damaged cord
or plug, after the appliance malfunctions, or if it has
been dropped or damaged in any manner. Return
appliance to manufacturer for examination, electrical
or mechanical adjustment, or repair.
10. Use appliance only for intended household use
as described in this manual. Any other use not
recommended by the manufacturer may cause
fire, electric shock, or injury to persons. The use
of attachments not recommended or sold by The
Holmes Group, Inc. may cause hazards.
11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level surface.
A waterproof mat or pad is recommended for under
the humidifier. NEVER place it on a rug or carpet,
or on a finished floor that may be damaged by
exposure to water or moisture.
13. DO NOT allow the Moisture Outlet to directly face
the wall. Moisture could cause damage, particularly
to wallpaper.
14. Humidifier should be unplugged when not in use.
15. NEVER tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water tank and moving the unit.
16. This humidifier requires daily and weekly maintenance
to operate appropriately. Refer to daily and weekly
cleaning procedures.
17. NEVER use detergents, gasoline, glass cleaner, furniture
polish, paint thinner, or other household solvents to clean
any part of the humidifier.
18. Excessive humidity in a room can cause water
condensation on windows and some furniture.
If this happens, turn the humidifier OFF.
19. Do not use humidifier in an area where humidity
level is in excess of 50%. Use the included
hygrometer, or purchase one at your local
hardware store or through Holmes, to measure
the humidity.
20. DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
your warranty. The inside of the unit contains no user
serviceable parts. All servicing should be performed
by qualified personnel only.
21. Never place housing under water flow or immerse
in liquids.
22. Do not plug in the cord with wet hands: electric shock
could result.
23. Do not pour water in any openings other than
the water tank.
24. To prevent damage to surfaces, do not place humidifier
under overhanging surfaces.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
Consumer Safety Information
Note: This is an electrical appliance and requires attention
when in use.
Note: If moisture forms on the walls or windows of the
room, turn off the humidifier. The room already has plenty
of humidity and additional moisture may cause damage.
Do not block air inlet or outlet.
Cord and Plug Installation Safety Instructions
The length of cord used on this appliance was selected
to reduce the hazards of becoming tangled in, or tripping
over a longer cord. If a longer cord is necessary an
approved extension cord may be used. The electrical
rating of the extension cord must be equal to or greater
than the rating of the humidifier. Care must be taken
to arrange the extension cord so that it will not drape
over the countertop or tabletop where it can be pulled
on by children or accidentally tripped over.
THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC
(Alternating Current)PLUG (a plug having one blade wider
than the other). This plug will fit into the power outlet only
one way. If the plug does not fit fully into the outlet,
reverse the plug. If it still does not fit, contact qualified
personnel to install the proper outlet.
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS
POLARIZED PLUG IN ANY WAY.
PLEASE READ AND SAVE THESE IMPORTANT
SAFETY INSTRUCTIONS
FEATURES - OPERATION REPLACING THE FILTER
CLEANING INSTRUCTIONS - STORAGE
REPLACING THE FILTER
Through normal use, waterborne minerals and sediment become
trapped in the wick filter. The harder your water, the greater the
amount of minerals in the water, and the more often you will need
to change your filter.
You will be able to monitor the life of the filter in your humidifier by
checking the Filter Check™ Indicator. When the unit is off, the Filter
Check™ Indicator will read in the OFF position. After 60 minutes of
use, Filter Check™ Indicator (refer to fig. 3 for close-up of indicator)
will move from the OFF position
and indicate your filter condition.
A brand new filter will register in
the blue section reading GOOD
filter. After frequent use of your
humidifier, the Filter Check™
Indicator will let you know when
the filter needs to be changed.
When the needle is in the red (CHANGE) section, this means the
proper amount of moisture is not getting into your air due to the
excessive minerals and sediment that have become trapped on your
filter. At this point, you should replace your filter. It is important to
change your filter as indicated to obtain stated performance level.
To replace the filter, follow the steps below.
1. Push the 1 Touch button for 2 seconds to turn the unit OFF
and disconnect from the electrical outlet.
2. Remove the tank and main housing to access the base tray.
3. Discard the old filter and follow weekly cleaning instructions.
4. Insert a new filter into the filter support in the base.
5. Replace the main housing and then the tank.
6. Repeat Operating Instruction steps.
It will take about 30 minutes for the humidifier to reach
maximum output.
You can obtain a new filter by calling 1-800-5-HOLMES in the USA
or by visiting your nearest retailer or authorized service center.
This humidifier takes model HWF65 replacement filter.
CLEANING AND MAINTENANCE INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry indoor
air. To get the most of the benefit from the humidifier and
avoid product failure, follow all maintenance instructions
carefully. If the recommended care and maintenance guidelines
are not followed, micro-organisms may be able to grow in the
water within the humidifier.
Daily Maintenance
1. Be sure the humidifier is switched OFF and disconnected from
the electrical outlet.
2. Lift off the tank and the housing of the humidifier. Remove filter
and place in sink or tub as the filter will release water when not
in the humidifier.
3. Carry the base and the tank to the sink, remove the wick filter,
then drain and rinse the base and tank thoroughly to remove
any sediment and dirt. Wipe clean and dry with a clean soft cloth
or paper towel. (DO NOT use metal cleaning utensils or abrasive
cleaners)
4. Put the filter back in the filter supports, replace the housing, then
refill the tank with cool tap water as instructed in filling the water
tank instructions.
Weekly Maintenance
Remove scale:
1. Repeat steps 1-3 above.
2. Clean the base by partially filling the base with one 8-oz cup
of undiluted white vinegar, or by using Cleanse Clean™
by Holmes. Let solution stand 20 minutes, clean all
interior surfaces with a soft brush.
3. Dampen a cloth with undiluted white vinegar and wipe out
entire base to remove scale.
4. Rinse with clean warm water to remove scale and the white
vinegar solution before beginning to disinfect the tank.
Disinfect tank:
1. Fill tank with 1/2 teaspoon of chlorine bleach and 1/2 gallon
of water.
2. Let the solution stand for 20 minutes, swishing every few minutes.
Wet all surfaces.
3. Empty the tank after 20 minutes, and rinse well with water until
the bleach smell is gone. Dry with a clean cloth or paper towel.
4. Refill the water tank with cool water; replace the housing
and the water tank. Repeat ALL Operating Instructions.
HOW COOL MIST WORKS
Your Holmes Cool Mist humidifier draws dry air through the rear air
intake grill area. This air is then passed through a moisture–laden
wick filter, which retains the minerals and deposits in the water.
The resulting moist air is directed back into the room from the
top air grill.
NOTE: This humidification system provides a cool, invisible moisture
output. It is normal not to see the mist.
NOTE: A humidity level below 20% can be unhealthy and
uncomfortable. The recommended humidity level is between
40%-50%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched OFF and disconnected from
the electrical outlet.
2. Select a location for your humidifier, on a flat surface, about 4"
away from the wall. Do not place your humidifier on furniture;
a floor location that will not be damaged by moisture is best.
3. Remove the water tank by holding the tank handle and lifting
straight upward (see figure 2).
4. Remove the main housing by lifting straight upward. Check
to see that the wick filter is properly in place. Replace the
humidifier housing.
FILLING THE WATER TANK
NOTE: This humidifier holds about 1 gallon of water in the tank
and humidifier base. The humidifier will produce up to 2.0 gallons
of moisture over a 24-Hour period, depending on the room humidity
and temperature.
1. Be sure the humidifier is switched OFF and disconnected from
the electrical outlet.
2. Remove the tank from the base by holding the handle
and lifting straight up (see figure 2).
3. Twist off the tank cap located on the bottom of the tank
by turning counter clockwise and fill the water tank with
cool, fresh water.
Do not fill with warm water as this may cause leaking.
4. After filling the tank, replace the tank cap by firmly turning
clockwise and then replace the water tank on the base.
The tank will immediately begin to empty into the base.
5. Plug the power cord into a 120V AC electrical outlet.
OPERATING INSTRUCTIONS
1. Move the Humidity Control Knob to the HI position. Move the
Humidity Control knob to the LO setting to lower the humidification
rate. Allow up to 30 minutes for the filter to fully absorb water
and the unit to produce the maximum moisture output.
NOTE: We recommend the use of the hygrometer which you can
purchase by calling 1-800-5-HOLMES. A humidity level below 20%
can be unhealthy and uncomfortable. The recommended humidity
level is between 40% and 50%.
2. When the water tank is empty, and the base is almost empty,
you need to refill the tank. The fan will continue to run to help
dry the humidifier. Shut off and unplug the unit. Please follow
the Daily Cleaning Instructions. Refill the tank as directed in
Pre-operating Instructions.
3. Make sure the unit is switched OFF, then plug into the electrical
outlet. Turn the power ON.
If you do not plan to use the humidifier for two or more days, make
sure any residual water is drained from the water tank, base and
wick filter to prevent algae or bacteria growth.
STORAGE INSTRUCTIONS
If your humidifier will not be in use for two days or more, or at the
end of the season follow these instructions.
1. Clean and dry the humidifier thoroughly as per the Weekly
Maintenance instructions above.
2. Let the humidifier dry completely before storing.
Do not store with water inside the base.
3. Do not store with the reservoir cap in place.
4. Throw away the wicking filter. Do not store with wick filter in place.
5. Store in a cool dry location.
Figure 1
A.Circular Filter
Supports
B.Circular
Extended Life
Filter
C. Humidifier
Base
B
C
A
Figure 2
A
B
C
D
E
A. Carry Handle
B. Humidifier Tank
C. Humidifier Housing
D.2-Speed Humidity
Control/Power Knob
E. Humidifier Base
F. Filter Check™
Indicator
F