/Off
1 TOUCH™ THERMOSTAT INSTRUCTIONS
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should always
be followed to reduce the risk of fire, electric shock, and injury to per-
sons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance directly into a
120V AC electrical outlet.
3. The heater is hot when in use. To avoid burns, DO NOT let bare skin
touch hot surfaces. If provided, use handles when moving this
heater. Keep combustible materials, such as furniture, pillows,
bedding, papers, clothes, and curtains at least 3 ft (0.9 m) from the
front of the heater and keep them away from the sides and rear.
4. DO NOT run cord under carpeting. DO NOT cover cord with throw
rugs, runners, or the like. Arrange cord away from traffic area and
where it will not be tripped over.
5. This heater is not intended for use in bathrooms, laundry areas and
similar indoor location. NEVER locate heater where it may fall into a
bathtub or other water container.
6. Extreme caution is necessary when any heater is used by, or near
children or invalids, and whenever the heater is left operating
and unattended.
7. Always unplug the heater when not in use.
8. When unplugging, be sure to pull by the plug and not the cord.
9. DO NOT insert or allow foreign objects to enter any ventilation or
exhaust opening as this may cause an electric shock or fire, or
damage the heater.
10. DO NOT operate heater with a damaged cord or plug, or after the
heater malfunctions, has been dropped or damaged in any manner.
Return appliance to manufacturer for examination, electrical or
mechanical adjustment, or repair.
11. A heater has hot and arcing or sparking parts inside.
DO NOT use it in areas where gasoline, paint, or flammable liquids
are used or stored.
12. Use appliance only for intended household use as described in this
manual. Any other use not recommended by the manufacturer
may cause fire, electric shock, or injury to persons. The use of
attachments not recommended or sold by The Holmes Group
may cause hazards.
13. DO NOT use outdoors.
14. To prevent a possible fire, DO NOT block air intakes or exhaust in
any manner. DO NOT use on soft surfaces, like a bed, where open-
ings may become blocked.
15. To disconnect heater, press and hold down MODE/OFF button for 2
seconds, then remove plug from outlet.
16. Avoid the use of an extension cord because the extension cord may
overheat and cause a risk of fire. However, if you have to use an
extension cord, the cord shall be No. 14 AWG minimum size and
rated not less than 1875 watts.
17. If the heater will not operate, see specific instructions on
Auto Safety Shut-off.
18. DO NOT attempt to repair or adjust any electrical or mechanical
functions on this unit. Doing so will void your warranty. The inside
of the unit contains no user serviceable parts. All servicing should
be performed by qualified personnel only.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
To take advantage of the 1 Touch™ Thermostat continue to press the
MODE/OFF button until the desired temperature is set in either the HIGH
(1500 Watt) or LOW (1000 Watt) setting. When ambient temperature
rises above the set temperature, the heater will stop. When the ambient
temperature drops below the set temperature, the heater will turn on
automatically.
Note: When the 1 Touch™ thermostat is set, either the HIGH or LOW
power light, and the set temperature light will remain lit during opera-
tion. (See fig. #1 and #2)
Note: It is normal for the heater to cycle ON and OFF as it maintains the
preset temperature. To prevent the unit from cycling, you need to raise
the thermostat setting.
THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC
(Alternating Current)PLUG (a plug having one blade wider
than the other). This plug will fit into the power outlet
only one way. If the plug does not fit fully into the outlet,
reverse the plug. If it still does not fit, contact qualified
personnel to install the proper outlet.
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS
POLARIZED PLUG IN ANY WAY.
PRE-OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Your heater is equipped with a technologically advanced 1 Touch™
electronic thermostat. You can set the heater to run continuously in man-
ual mode or set the 1 Touch™ Thermostat to your desired temperature
setting. The 1 Touch™ thermostat will automatically turn the heater ON
or OFF depending on the preset comfort level. The comfort level ranges
between 60º and 80º Fahrenheit.
Manual Mode Instructions:
1. Plug the heater into a 120V AC electrical outlet.
2. To start the unit, push the MODE/OFF button once for the HIGH
(1500 Watts) manual setting. (See fig. #1 and #2)
3. Press the button again for the LOW (1000 Watts) manual setting.
(See fig. #1 and #2)
4. To stop the unit, press and hold the button for two seconds or keep
pressing the button until all the temperature indicators are OFF.
Note: The Power Light will remain lit while the unit is plugged in. In
Manual Mode, only the LOW or HIGH power light will be lit.
1. Carefully remove your heater from the box. (Please save the carton
for off-season storage.)
2. Place heater on firm level surface.
3. Avoid overloading your circuit by not using other high wattage appli-
ances in the same outlet. At 1500 Watts, this unit draws 12.5 Amps.
ILLUSTRATIONS
A. WATTAGE
LIGHTS
B. MODE/OFF
CONTROL
C. THERMOSTAT
LIGHTS
D. CARRY HANDLE
(NOT VISIBLE)
E. POWER LIGHT
Figure 1
A
B
C
Figure 2
CONTROL PANEL CLOSE-UP
TROUBLESHOOTING
If your heater fails to operate:
• Make sure the electrical outlet or circuit breaker is working.
• Check for obstructions. If you find an obstruction turn the heater
OFF, and UNPLUG THE UNIT. Carefully remove the obstruction and
follow the reset instructions.
• The thermostat might be set too low. Press the MODE/OFF button
until the heater restarts.
Please DO NOT attempt to open or repair the heater.
Please see the Warranty for Service Instructions.
AUTO SAFETY SHUT-OFF WITH CERAMIC CONTROL
This heater is equipped with a patented, technologically-advanced, safety
system that requires the user to reset the heater if there is a potential
overheat situation. When a potential overheat temperature is reached,
the system will automatically shut the heater off. It can only resume
operation when the user resets the unit.
To Reset the Heater:
1. Unplug the unit.
2. Wait 10 minutes for the unit to cool down.
3. After the 10 minutes, plug the unit in again and operate normally.
Note: 1 Touch™ has memory. The 1 Touch™ Thermostat will remember
the previous temperature setting after the unit has been turned off.
However, if the unit is unplugged, the 1 Touch™ Thermostat will be reset
and will no longer remember the previous temperature setting.
CLEANING/MAINTENANCE
During Season Care:
1. Always unplug the heater, before moving or cleaning.
2. Carefully wipe the unit with a soft, damp cloth. Please be very
cautious near the motor and heating elements.
3. NEVER use abrasive or flammable solvents to clean the unit.
4. After cleaning, be sure to completely dry the unit with a cloth or
towel.
After Season Care:
1. Store heater in a cool, dry location.
2. Holmes recommends that you store the unit in its original carton.
A
B
C
D
A. SET TEMPERATURE
LIGHT
B. LOW POWER
(1000 WATTS)
C. HIGH POWER
(1500 WATTS)
D. MODE/OFF
CONTROL
E. POWER LIGHT
D
E
E