Holmes HFH6402/6408 Fan User Manual


 
PLEASE READ AND SAVE THESE
IMPORTANT SAFETY INSTRUCTIONS
FEATURES - OPERATIONSFEATURES - OPERATIONS
When using electrical appliances, basic safety precautions should
always be followed to reduce the risk of fire, electric shock, and
injury to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance directly into
a 120V AC electrical outlet.
3. The heater is hot when in use. To avoid burns, DO NOT let bare
skin touch hot surfaces. If provided, use handles when moving
this heater. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes, and curtains at least 3 ft (0.9
m) from the front of the heater and keep them away from the
sides and rear.
4. DO NOT run cord under carpeting. DO NOT cover cord with
throw rugs, runners, or the like. Arrange cord away from
traffic area and where it will not be tripped over.
5. This heater is not intended for use in bathrooms, laundry areas
and similar indoor location. NEVER locate heater where it may
fall into a bathtub or other water container.
6. Extreme caution is necessary when any heater is used by, or
near children or invalids, and whenever the heater is left
operating and unattended.
7. Always unplug the heater when not in use.
8. When unplugging, be sure to pull by the plug and not the cord.
9. DO NOT insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock or fire,
or damage the heater.
10. DO NOT operate heater with a damaged cord or plug, or after
the heater malfunctions, has been dropped or damaged in
any manner. Return appliance to manufacturer for examination,
electrical or mechanical adjustment, or repair.
11. A heater has hot and arcing or sparking parts inside. DO NOT
use it in areas where gasoline, paint, or flammable liquids are
used or stored.
12. Use appliance only for intended household use as described in
this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury to
persons. The use of attachments not recommended or sold by
The Holmes Group may cause hazards.
13. DO NOT use outdoors.
14. To prevent a possible fire, DO NOT block air intakes or
exhaust in any manner. DO NOT use on soft surfaces, like a
bed, where openings may become blocked.
15. To disconnect heater, turn controls to OFF, then remove plug
from outlet.
16. Avoid the use of an extension cord because the extension cord
may overheat and cause a risk of fire. However, if you have
to use an extension cord, the cord shall be No.14 AWG
minimum size and rated not less than 1875 watts.
17. If the heater will not operate, see specific instructions on Auto
Safety Shut-off.
18. DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void your
warranty. The inside of the unit contains no user serviceable
parts. All servicing should be performed by qualified
personnel only.
19. Discontinue use if plug or outlet is hot. It is recommended that
the outlet be replaced if plug or outlet is hot to touch.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC
(Alternating Current) PLUG (a plug having one blade wider
than the other). This plug will fit into the power outlet only
one way. If the plug does not fit fully into the outlet, reverse
the plug. If it still does not fit, contact qualified personnel to
install the proper outlet.
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS
POLARIZED PLUG IN ANY WAY
This heater is equipped with a patented, technologically-advanced
safety system that requires the user to reset the heater if there is a
potential overheat situation. When a potential overheat temperature
is reached, the system will automatically shut the heater off. It can
only resume operation when the user resets the unit.
To Reset the Heater:
1. Unplug the heater and wait 10 minutes for the unit to cool down.
2. After the 10 minutes, plug the unit in again and operate normally.
Tip-Over Shut-Off:
When the unit is accidentally knocked over, it will instantly shut
off. To reset, simply place the heater in an upright position. Press
the MODE button and operate normally.
PRE-OPERATING INSTRUCTIONS
1. Carefully remove your heater from the box. Please save the
carton for off-season storage.
2. Make sure the unit is in the OFF position before plugging the
heater into the outlet.
3. Place heater on firm level surface.
4. Avoid overloading your circuit by not using other high wattage
appliances in the same outlet. At 1500 watts, this unit draws
12.5 Amps.
NOTE: The power light will remain lit while the heater is plugged in.
AUTO SAFETY SHUT-OFF WITH MANUAL RESET
AccuTemp Plus
DIGITAL THERMOSTAT
Your heater is equipped with an AccuTemp Plus
Digital
Thermostat that allows you to set your heater to your precise
comfort level.
Setting the AccuTemp Plus
thermostat:
1. Press the Mode Button once for manual HI power. The heater
will run continuously on HI.
2. Press the Mode Button again for manual LO power. The heater
will run continuously on LO.
3. Press the Mode Button for a third time for Auto Mode HI
Power (AH) or press again for Auto Mode LO Power (AL). In
either of these modes you may then press the up, and down
buttons to reach your desired temperature.
4. Once you have reached your desired temperature, the display
will return to current room temperature and gradually
increase until the room has reached the preset temperature.
5. If the unit will not start in the AccuTemp Plus
mode, please
make sure the “set temperature” is higher than the current
room temperature.
NOTE: It is normal for the heater to cycle ON and OFF as it
maintains the preset temperature. To prevent the unit from
cycling, you need to raise the thermostat setting. When the preset
temperature is reached, the fan will run for 30 seconds without
heat. This cool down process ensures an accurate and consistent
temperature reading. If you unplug the heater, you will have to
reset the AccuTemp Plus
thermostat again by following the
above instructions.
NOTE: To shut the unit off at any time, press and hold the mode
button down for two seconds. For 6408 only, after heater is
turned off, fan will run for 30 seconds to cool unit.
NOTE: AccuTemp Plus
has memory. The AccuTemp Plus
thermostat will remember the previous temperature setting after
the unit has been turned off. However, if the unit is unplugged,
the AccuTemp Plus
thermostat will be reset and will no longer
remember the previous temperature setting.
Figure 2
HFH6408 Control Panel Close-Up
TECHNICAL SPECIFICATIONS
• Wattage: 1500W (+5% –15%)
• Working Voltage: 120V AC/60Hz
USING THE PROGRAMMABLE TIMER
AccuTemp Plus
allows the user to program the heater to turn on
at a preset time, or turn off after a set amount of time.
Setting the Off Timer:
1. Select the Mode and or temperature you wish the heater to
run in.
2. While the heater is running, press and hold the up and down
buttons simultaneously.
3. By pressing the up and down buttons, program the heater to
turn off up to 16 hours from the current time in increments
of 1 hour.
4. After setting the timer, the LED display will return to show the
current room temperature. For HFH6408 only, a LED will
illuminate to show that the timer is activated.
5. After the predetermined length of time has passed, the heater
will automatically shut off.
Setting the On Timer:
1. While the heater is off, press and hold the up and down
buttons simultaneously.
2. By pressing the up and down buttons, program the heater to
turn on up to 16 hours in advance of current time in
increments of 1 hour.
3. After the preset length of time has passed, the heater will
automatically turn on at the last mode setting that was
programmed. If no program was set, the heater will turn on
Auto Mode HI Power at 75° for a preset time of 2 hours.
OSCILLATION INSTRUCTIONS
1. Select the desired control setting and press or switch the
oscillation button to the ON position.
2. To stop oscillation, press or switch the oscillation button to OFF.
3. Please do not manually turn the unit; it is designed to turn
only by motorized oscillation.
REMOTE CONTROL INSTRUCTIONS (For
HFH6408 only)
The remote control for this unit has the capability of controlling
every function from a distance. Please note this remote control
will not work through walls.
Insert 2 "AAA" batteries (not included) into the remote control.
POWER: To turn the unit on or off press the Power button.
MODES: To scroll through the various modes OF, HI, LO, AH and
AL press the Mode button until you reach your desired setting.
OSCILLATION: To start oscillation, press the OSC. button once.
To stop oscillation press the button again.
TO INCREASE OR DECREASE TEMPERATURE: To increase
the temperature setting that you desire press the upward facing
triangle marked Temp Up. To decrease the temperature setting
that you desire press the downward facing triangle marked Temp
Down.
TIMER: To activate the timer from the remote control, press the
Temp Up and Temp Down buttons at the same time. This will give
you the ability to have your heater program to turn on or off in
1 hour increments up to 16 hours. For more information see the
Programmable Timer instructions above.
BATTERY WARNING:
DO NOT mix old and new batteries.
DO NOT mix alkaline, standard (carbon-zinc), or rechargeable
(nickel-cadmium) batteries.
Figure 3
MODE BUTTON
TEMP/TIMER DOWN BUTTON
OSCILLATION BUTTON
TEMP/TIMER UP BUTTON
Figure 1
HFH6402 Control Panel Close-Up
MODE BUTTON TEMP/TIMER DOWN BUTTON
OSCILLATION BUTTON TEMP/TIMER UP BUTTON
HFH6402/640803EM3.qxd 9/19/03 3:50 PM Page 2