Holmes HAP625 Air Cleaner User Manual


 
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance directly into a
120V AC electrical outlet.
3. If the filter is covered by a bag when shipped: Remove plastic bag
over filter before use.
4. Keep the cord out of heavy traffic areas. To avoid fire hazard,
NEVER put the cord under rugs, near heat registers, radiator, stoves,
or heaters.
5. To protect against electrical hazards, DO NOT immerse in water or
other liquids. Do not use near water.
6. Close supervision is necessary when any appliance is used by or near
children, or by disabled people.
7. Always unplug the air purifier before moving it, opening the grill,
changing filters, cleaning, or whenever the air purifier is not in use.
Be sure to pull by the plug and not the cord.
8. NEVER drop or insert any object into any openings.
9. DO NOT operate any appliance with a damaged cord or plug, if
motor fan fails to rotate, after the appliance malfunctions, or if it has
been dropped or damaged in any manner. Return appliance to man-
ufacturer for examination, electrical or mechanical adjustment, or
repair.
10.Use appliance only for intended household use as described in this
manual. Any other use not recommended by the manufacturer may
cause fire, electric shock, or injury to persons. The use of attach-
ments not recommended or sold by The Holmes Group (or Bionaire)
may cause hazards.
11.DO NOT use outdoors.
12.NEVER block the air openings, grilles/outlets or place on a soft sur-
face such as a bed or sofa, as this could cause the unit to tip over,
blocking the Air Intake Opening/Grill.
13.Keep unit away from heated surfaces and open flames.
14.DO NOT attempt to repair or adjust any electrical or mechanical func-
tions on this unit. Doing so will void your warranty. The inside of
the unit contains no user serviceable parts. All servicing should be
performed by qualified personnel only.
15.WARNING: To reduce the risk of fire or electric shock, DO NOT use this
air purifier with any solid-state speed control device.
16. DO NOT place anything on top of unit.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
OPERATING INSTRUCTIONS
FILTER LIFE INDICATOR
PRE-OPERATING INSTRUCTIONS
HARMONY BACKGROUND
First, thank you for choosing a Holmes Harmony Air Purifier.
The Harmony air purifier was created because consumers, like
you, provided a lot of feedback about what you wanted in an
air purifier. With the features consumers want in mind, we
worked with sound experts to make the unit quieter, engineers
to make it smaller with more advanced technologies. We created
a patented modular filter system for easier filter replacement.
The result is an air cleaner that is in harmony with your envi-
ronment, it cleans your air and fits your life.
TROUBLESHOOTING
CLEANING AND MAINTENANCE INSTRUCTIONS
1) Turn the air purifier off and unplug it before cleaning.
2) The outside of the air purifier can be cleaned with a soft,
clean dampened cloth.
3) The filtered air outlet on the top of the unit can be cleaned of
dust with a small, soft brush.
4) If you wish to clean the inside of the air purifier, please only
use a dry, soft cloth to wipe it down.
1) Select location where air intake grill and filtered air outlet
are not obstructed.
2) Plug into a 120V AC electrical outlet.
3) The air purifier is now ready for your use. Please set the
unit to the desired speed setting; High (IIII), Medium (III),
Low (II), or Sleep (I).
The Filter life indicator uses a series of lights to give you an indi-
cation of the remaining filter life. With new filters, the top light
will be illuminated green. As filter life progresses the filter life
indicator will move to yellow, and your carbon and HEPA filters
should be checked. When the filter life indicator light is red, it is
time to change the filters.
NOTE: The door should not be opened when the unit is
on its side.
1) After removing the unit from the box, take the plastic
covering off the unit.
2) Place unit with air intake grill pointing up.
3) Open the door of the air purifier.
4) The Carbon filters, which are packed in a plastic bag in the
box, should be put on each of the HEPA filters. The plastic
tabs on the HEPA filter will hold the carbon in place (fig. 1).
5) Close the air purifier door by pushing firmly against the right
hand side of the door.
FILTER REPLACEMENT INSTRUCTIONS:
1) On average, HEPA filters need to be replaced every 12-18
months. Carbon filters need to be replaced every 3-6
months. Filter life will vary depending on air quality and
usage.
2) Turn off and unplug the air purifier before attempting to
replace the filters.
3) Remove each of the filters from the unit by pulling gently
towards you.
4) To replace the carbon filter, simply remove the old carbon
filter and insert a new carbon in its place, using the plastic
tabs as a guideline (see Figure 1).
5) To replace the HEPA filter, discard the old HEPA filters. Put
the carbon filter back on the HEPA filter. Insert the new
HAPF600 HEPA filter into the unit, by sliding it onto the
hang tabs.
6) After replacing the HEPA filters, RESET the Filter Life
Indicator by inserting a small object (such as a pin or paper
clip) into the hole marked RESET.
Replacement filters are as follows:
HAPF600 HEPA Filter
HAPF600D HEPA Filter (2 pack)
HAPF60 Carbon Filter
These filters can be purchased at a retailer near you or
by calling 1-800-5-HOLMES.
NOTE: Carbon and HEPA Filters are not washable and
should be replaced at the recommended intervals.
PROBLEM SOLUTION
Unit will not operate Check to make sure the unit is
plugged in.
Check to make sure the unit is on
by turning the knob.
If the door is ajar the unit will not
operate. Make sure the filters are
properly installed and firmly close
the door.
Decreased air flow If the Filter Life Indicator is red,
the HEPA filters need to be changed.
If the filters have not been changed
in a year or more, change the
HEPA filters.
Check to ensure nothing is blocking
air inlet and filtered air outlet.
Ensure carbon filters are changed
every 3-6 months.
FEATURES
Dual Position- the air purifier can stand upright or lie on its
side. Also designed to fit with its back flush against the wall.
When positioning the unit,
please be sure the air inlet
grill, filters and air outlet are
not blocked to ensure maxi-
mum airflow.
Equipped with GE motor
for quieter performance and
the added durability neces-
sary for continuous use.
Filter Life Indicator- The filter life indicator will be green
when the filters are new or in good condition. Over a period of
time, the filters performance will begin to decrease. At this
point the filter life indicator will be yellow. Eventually, the fil-
ter life indicator will be red, indicating it is time to replace the
filters.
Figure 3
Figure 2
Figure 1
F
G
H
I
D
C
A
B
E
A. HEPA FILTER
B. CARBON FILTER
C. HANG TABS
D. AIR INTAKE GRILL
E. FILTERED AIR
OUTLET
F. SPEED CONTROL
KNOBS
G. FILTER LIFE
INDICATOR
H. RESET BUTTON
I. POWER CORD
(not shown)
THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC
(Alternating Current) PLUG (a plug having one blade wider than
the other). This plug will fit into the power outlet only one way.
If the plug does not fit fully into the outlet, reverse the plug. If
it still does not fit, contact qualified personnel to install the prop-
er outlet. DO NOT DEFEAT THE SAFETY PURPOSE OF THIS
POLARIZED PLUG IN ANY WAY.
Page 2 Page 3
Cord and Plug Installation Safety Instructions
The length of cord used on this appliance was selected to reduce the haz-
ards of becoming tangled in, or tripping over a longer cord. If a longer
cord is necessary an approved extension cord may be used. The electri-
cal rating of the extension cord must be equal to or greater than the rat-
ing of the air purifier. Care must be taken to arrange the extension cord
so that it will not drape over the countertop or tabletop where it can be
pulled on by children or accidentally tripped over.