The heater is equipped with a pump which circulates water inside the booster heater and maintains a
uniform water temperature in the tank. Depending on the distance from the heater to the dishwasher,
it may be necessary to run empty rack(s) to purge the supply line if the indicated rinse water
temperature is lower than the required 180°F. For this reason, it is best to locate the booster heater
as close as possible to the dishwasher. If the booster heater is located more than 10 feet from the
dishwasher, an additional recirculation system (supplied by others) may be installed (Fig. 7).
SHOWN WITH OPTIONAL WATER HAMMER ARRESTOR KIT
TYPICAL PIPING FOR RECIRCULATION SYSTEM
WHEN BOOSTER HEATER IS GREATER THAN 10 FEET FROM DISHWASHER
Fig. 7
SUGGESTED PUMP FLOW: 2 – 5 GPM.
CONSULT PLUMBER FOR SPECIFIC
RECOMMENDATIONS.
PL-53294
180 F to
Dishwasher
Union
Ball
Valve
Union
Water Shock
Absorber
Floor Drain
140 F
Inlet
Ball Valve
Pressure
Gauge
Pressure
Regulator
PL-53293
Pump &
Motor
Water Shock
Absorber
140 F
Inlet
180 F to
Dishwasher
Ball Valve
Union
Ball
Valve
Union
Floor Drain
Pressure
Gauge
Pressure
Regulator