Hisense Group KFR 3201GWE Air Conditioner User Manual


 
Night Setback / Simultaneous Use Energy Saving
C
1HR
ON/OFF
TEMP
HIGH
POWER
FLAP
ON
OFF
SET CANCEL
SLEEP
A/C SENSOR
ACL
BATTERY
FAN
SPEED
MODE
AUTO
AUTO
Night Setback Mode
Night Setback Mode is used for saving energy. Press the SLEEP button
in operation. The mark appears in the display. To release the night
setback function, press the SLEEPbutton again.
NOTE This function loses in automation or airflow mode.
A.In Cooling and DRY Mode:
When the night setback mode is selected, the air conditioner
automatically raises the temperature, setting 1 when 60
minutes have passed, after the selection was made ,and then
another 1 after another 60 minutes have passed and at last
stops operating automatically
after lasting about 6 hours at this temperature, regardless of
the indoor temperature when night setback was selected. This
Enables you to save energy without sacrificing comfort. This
Function is convenient when gentle cooling is needed.
12345678
12345678
Setting
temperature
Stop operating
Automatically
(Hour)
Press the SLEEP button
B.In heating mode:
When the night setback mode is selected, the unit automatically
drops the temperature setting 2 when 1 hour has passed
when the selection was made, and another 2 after another 1
hour has passed, and then raises 1 after 3 hours, at last stops
operating automatically at this temperature after another 3 hours.
Press the SLEEP button
(Hour)
Stop operating
Automatically
Setting
temperature
12
1
1
1
2
2