Hisense Group KFR 25GWE Air Conditioner User Manual


 
Schematic Diagram
2. Refrigerant Flow Diagram
KFR-33GWE
AC,230V/50Hz
1220W/1260W
3300W/3550W
8m/80
15m
3
450m /h
R22/1.30kg
1. Main specifications of the product
Type
Power source
Power consumption of input
(cooling/heating)
Power
(cooling/heating)
Air flow (high)
Refrigeration dose/consumption
Maximum remote control range/
angle range
Maximum length of the connect tube
19
KFR-28GWE
AC,230V/50Hz
1000W/1020W
2800W/3200W
8m/80
15m
3
450m /h
R22/1.27kg
KFR-25GWE
AC,230V/50Hz
950W/950W
2500W/3000W
8m/80
15m
3
450m /h
R22/0.84kg
KFR-2101GWE
AC,230V/50Hz
750W/710W
2100W/2300W
8m/80
15m
3
340m /h
R22/0.70kg
KFR-3201GWE
AC,230V/50Hz
1250W/1400W
3200W/3750W
8m/80
15m
3
420m /h
R22/1.18kg
Indoor unit
Heat exchanger
Heat exchanger
Wide tube
Narrow tube
Outdoor unit
Wide
service
valve
Accumulator
Compressor
4-way valve
Capillary
Narrow
service
tube
Cooling cycle
Heating cycle
Capillary
Check valve
3. Permitted ambient temperature for the air conditioner is following:-7 ~+43 (GB/T 7725-1996)