4
Humidifier
Humidifier
Humidifier
Alternate
location
"A" coil
Air cleaner
Air cleaner
Air cleaner
Air cleaner
Bypass duct
Bypass duct
Bypass duct
Bypass
duct
Humidifier
Humidifier
15. When installing this humidifier above electric
warm air heating elements or where water
damage could occur from accidental overflow,
connect a 1/2” drain hose to the brass overflow
nipple.
16. Do NOT solder the drain line directly to the
humidifier because heat can warp and damage
the pan.
17. Mount the Increaser to the unit by inserting the
small end of the Increaser into the open end of
the unit and securing with clamp.
18. Attach 7” bypass flex or metal duct (not
provided) to Increaser and Return Air Flange.
19. Insert the window panel by reversing Step #1.
Saddle valve assembly