Hellenbrand H-200L Series Water System User Manual


 
DEALER NAME:
Hellenbrand, Inc.
404 Moravian Valley Rd
Waunakee, WI 53597
www.hellenbrand.com
73-047L
1/08-LBRY
Web Brochure Only
HELLENBRAND WARRANTY
Go to www.hellenbrand.com for full details.
FLOW PEAK FLOW BACK BRINE TANK
1
DEMAND CAPACITY RATE RATE WASH MINERAL TANK SALT
MODEL MINERAL LOW SALT MED. SALT HIGH SALT @ @ RATE TANK SIZE STORAGE
NAME CU. FT. GRAINS/LBS. GRAINS/LBS. GRAINS/LBS. 15 PSI 25 PSI GPM (INCHES) (INCHES) (POUNDS)
H200L-60 2 38,000/12 56,000/20 64,000/30 34 44 4.2 1354 18x40 330
H200L-90 3 57,000/18 84,000/30 96,000/45 34 44 4.2 1465 18x40 300
H200L-120 4 76,000/24 112,000/40 128,000/60 41 53 5.3 1665 24x41 640
H200L-150 5 95,000/30 140,000/50 160,000/75 46 59 7.5 1865 24x50 750
H200L-150-21 5 95,000/30 140,000/50 160,000/75 54 68 9.0 2162 24x50 750
H200L-180 6 114,000/36 168,000/60 192,000/90 44 56 7.5 1865 24x50 750
H200L-180-21 6 114,000/36 168,000/60 192,000/90 53 67 9.0 2162 24x50 750
H200L-210 7 133,000/42 196,000/70 224,000/105 51 66 9.0 2162 24x50 710
H200L-240 8 152,000/48 224,000/80 256,000/120 58 74 12.0 2472 24x50 680
H200L-270 9 171,000/54 252,000/90 288,000/135 55 72 12.0 2472 30x50 1110
H200L-300 10 190,000/60 280,000/100 320,000/150 54 70 12.0 2472 30x50 1110
Specications
H200L Features and Benets
2.0" Inlet & Outlet provides higher service ows with
less pressure drop
1.5" Distributor Pilot
12-Volt Operation
Electronic Meter Demand with Calendar Day Override
Scrolling User Screen shows capacity remaining, time
of day and ow rate
12-Volt Relay Driver allows dry contact signal
Service Interval Screen reminds you to call for
preventative maintenance service
Differential Pressure Switch Capability
Fully Programmable Cycle Position and Times
Nine Cycle Control
Soft Water Brine Tank Re-Fill
Multiple Backwash and Rinse Capabilities
Quiet Operation
Variable Reserve automatically adjusts to changing
water usage patterns.
Several programming options including: variable re
-
serve, xed reserve, calendar day override, delayed or
immediate regeneration.
Diagnostics
–Days since last regeneration
–Gallons since last regeneration
–Gallon reserve capacity last 7 days
–63 Days history of daily totals usage
–Maximum ow rate for the last seven days
–Total number of regenerations
–Total days in service
–Total gallons processed
Permanent memory backup of all programming
10 Year Battery Life - 2-1/2 years Time of Day Backup
Uses less than $2 of electricity per year
System Designs Options
Single
Twin Parallel
Twin Alternating
Meter Accuracy
Model: H200L
Flow Ranges 1.5-75 GPM
Accuracy: ±5%
1
Suggested brine tank size with grid plate option.
H200L Standard Valve/Tank Thread Connection