Hellenbrand 6.5 Water System User Manual


 
ProMate 6.5; Elegant Simplicity, Raw Power, Premium Resin
Superior Flow Technology
Hellenbrand’s distribution plate has 56% more surface area
on 10” diameter systems than standard systems with a cone
type distributor, and runs the full width of the tank diameter
for signicantly improved performance.
Improved bed expansion in backwash provides
better cleaning of the bed.
Less water is required to regenerate.
Array
(starting at
center)
% Increase of open
area with respect to
Array No. 1
Array No. 1 -
Array No. 2 100%
Array No. 3 200%
Array No. 4 300%
Array No. 5 400%
Array No. 6 500%
Standard TankVortech™ 10” Mid Plate
Premium 10% Resin
We use premium 10% crosslinked resin vs. most of our
competitors that use 8% or less.
What does this mean?
10% resin is used for a lot of commercial applications,
because it is stronger and lasts longer. It resists mushing
and jelling from chemicals and physical breakdown.
Damaged resin means you will use more salt and waste
more water when recharging the resin for softening.
You also have better pressure over the life of your softener.
Fewer Parts = Fewer Problems
• Modular Design
• Non-Corrosive Valve Body & Internals
• One Piece Seal Assembly
• No Nuts, Bolts, Screws or Micro-Switches
• Disassemble and Reassemble in Minutes
ProMate 6.5 Series - Simplicity with High Performance
The Hellenbrand ProMate 6.5 Electronic On Demand System
incorporates all of the best engineering features of our ProMate
6.0 Series with additional “High Performance” designs, that
provides higher capacities or more simply put “better gas
mileage” and less salt used.
We have incorporated small but critical design features learned
from months of testing to increase the operating efciencies
(grains of softening capacity per lb. of salt used) to nearly
5,000 grains per lb. of salt using counter-current or upow
regeneration.
The PM6.5 uses upow or counter-current regeneration,
passing the regenerate through unused resin at the bottom
of the tank, pushing the hardness minerals up through the
exhausted portion of the resin bed for a more efcient
regeneration.
This allows the water leaving the tank during service to pass
through the most efcient zone at the bottom of the tank.
Variable reserve automatically adjusts to your changing
water usage patterns for each day of the week, providing
added savings.
This provides better salt efciencies, better water quality
and less water used for regeneration.
Regenerant
In
Downow
(Cocurrent)
Upow
(Countercurrent)
Marginally
Regenerated
Zone
Highly
Regenerated
Zone
Ion Exchange
Resin
Hardness
Minerals
Out
Regenerant
In
Hardness
Minerals
Out