Heath Zenith UT-5105-WH Home Safety Product User Manual


 
5
598-1292-03
SPECIFICATIONS
Horizontal Range . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
[varies with surrounding
temperature]
Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80°
Vertical
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
Maximum each bulb holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO, and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 20 minutes
DualBrite
®
Timer . . . . 3, 6 hours, Dusk-to-Dawn
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
SYMPTOM
Lights will not come
on.
Lights come on
in daylight.
Lights come on for
no apparent rea-
son.
Lights turn off too
late in Dusk-to-
Dawn setting
POSSIBLE CAUSE
1. Light switch is turned off.
2. Flood ligh t is lo ose or
burned out.
3. Fuse is blown or circuit breaker
is turned off.
4. Daylight turn-off is in effect
(Re-
check after dark).
5. Incorrect circuit wiring, if this is
a new installation.
6. Re-aim the sensor to cover de
-
sired area.
1. Light control may be installed in
a relatively dark location.
2. Light control is in Test.
(Set control switch to an
ON-TIME position).
1. Light control may be sensing
small animals or automobile
traffic (Re-aim sensor).
2. Range is set t oo hig h.
(Reduce Range).
3. D
ualBrite
®
Timer is on.
1. Sensor is in a relatively dark
location. (Relocate sensor, or
use 3 hr or 6 hr setting.)
SYMPTOM
Lights stay on
continuously.
Lights flash on
and off.
Lights flash
once, then stay
off in Manual
Mode.
TROUBLESHOOTING GUIDE
POSSIBLE CAUSE
1. A flood bulb is positioned too close to
the sensor or pointed at nearby objects
that cause heat to trigger the sensor.
(Reposition the bulb away from the
sensor or nearby objects).
2. Light control is pointed toward a heat
source like an air vent, dryer vent, or
brightly-painted heat-reflective surface.
(Reposition sensor. Reduce Range).
3. Light control is in Manual Mode.
(Switch to Auto.)
1. Heat or light from the bulbs may be
turning the light control on and off.
(Reposition the bulbs away from the
sensor).
2. Heat being reflected from other objects
may be affecting the sensor. (Reposi-
tion sensor).
3. Light control is in the Test mode and
warming up. (Flashing is normal under
these conditions. Turn Boost off.)
4. Light may be leaking through the flood
-
lamp reflectors. (Replace the bulbs
with new high quality PAR 38 bulbs or
make sure the metal bulb protectors
are installed).
1. Sensor is detecting its own lights.
(Reposition bulbs to keep area below
the sensor relatively dark.)