Heath Zenith SL-6107 Home Security System User Manual


 
595-4514-13
-8-
For single switch in-
stallations, connect
the wall switch as
shown here.
If you want to have mo-
tion sensors at both
3-way switches, con-
nect them as shown
below. The minimum
wattage may increase
to 100 W for fluores-
cent and 50 W for in-
candescent lighting.
SPECIAL INSTALLATIONS
AUTO
OFF
ON
SINGLE SWITCH INSTALLATION
FROM
POWER
SOURCE
BLACK
BLACK
WHITEWHITE
BROWN
SL-6107
RED
BLACK
EXISTING LIGHT SWITCH CONFIGURATION
WHITE
FROM
POWER
SOURCE
BLACK
WHITE
RED
(In Wall)
RED (In Wall)
BLACK
WHITE
BLACK
2 SWITCH INSTALLATION
AUTO
OFF
ON
WHITE
FROM
POWER
SOURCE
BLACK
WHITE
SL-6107
WHITE
BLACK
AUTO
OFF
ON
BLACK
BLACK
BROWN
SL-6107
RED
(From 6107)
BROWN
RED
(From 6107)
*COMMON *COMMON
*COMMON-Used for illustrative Purposes Only. Check Your Switch. The common may be in a different
location, depending on the brand of your switch.
RED is used to represent the second wire between two standard three-way switches. This may not be the
color used in all installation. If you are not sure about your wiring, call an electrician for installation help. There
is also a RED wire on the SL-6107 switch. Check the instructions above closely and do not confuse the two.