Heath Zenith SL-5525 Indoor Furnishings User Manual


 
© 2004 DESA Specialty Products™ 595-5295-11
1 Halogen
Lamp
Sensor
Light Control
Requirements
The Light Control requires 120-volts AC.
If you want to use Manual Mode, the control must be
wired through a switch.
Some codes require installation by a qualified
electrician.
This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Motion Sensing
Halogen Fixture
Model SL-5525
3 Wire
Connectors
6 Screws
(3 sizes included)
Gasket
Mounting Bolt
Mounting Strap
OPERATION
* resets to Auto Mode at dawn.
MANUAL MODE
ON-TIME
10 5 1 TEST
10 5 1 TEST
ON-TIME
TEST
... back on.
AUTO
1 Second OFF
then...
Move ON-TIME Switch to
1, 5, or 10 minutes
Mode Switch Summary
Flip light switch off
for one second
then back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Light Shield
Plastic Hanger
Rubber Plug
Mode: On-Time: Works: Day Night
Test 5 Sec x x
Auto 1, 5, 10 min. x
Manual Until Dawn* x
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
This package includes: