Motion
Motion
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
1
/
2
minute calibration period
before it will detect motion.
When first turned on
wait 1
1
/
2
minutes.
Bottom of Sensor
Avoid aiming the sensor at:
Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
Maximum Range
8 ft.
(2.4 m)
Maximum
Coverage Angle
70 ft. 100 ft.
(21 m) (30.5 m)
Boosted
Least Sensitive Most Sensitive
Sensor
The detector is less sensitive to motion directly towards it.
Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.
Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cov-
erage area. Keep the sensor
at least 1" (2.5 cm) away
from the lamps.
Adjust the RANGE as
needed.
RANGE set too high
may increase false
triggering.
Secure the sensor head's
aim by tightening the
clamp screw. Do not over-
tighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5 or 20 minutes).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
[varies with surrounding
temperature]
Sensing Angle . . . . . . Up to 240°
Electrical Load. . . . . . Up to 300 W Max. Incandescent
[Up to 150 W Max. each lamp
holder].
Power Requirements. 120 VAC, 60 Hz
Operating Modes. . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1 , 5, 20 minutes
DESA Specialty Products™ reserves the right to
discontinue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.
240°
B
O
O
S
T
MAX
MIN
RANGE
ON - TIME
TEST 1 5 20
MINUTES
Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.