SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 60 ft. (18.3 m); [varies
with surrounding temperature]
Sensing Angle . . . . . . . Up to 110°
Electrical Load. . . . . . . Up to 300 Watts Maximum
Tungsten
Power Requirements. . 120 VAC, 60 Hz
Operating Modes. . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . 1, 5 or 10 minutes
Sensitivity . . . . . . . . . . Adjustable
Replacement lamp . . . T 300W (or less) halogen 120
VAC
DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
Maximum
Range
110°
Maximum
Coverage Angle
NOTE: Sensor requires about 1
1
/
2
minutes to calibrate
before it will detect motion. When first turned
on, wait about 1
1
/
2
minutes.
Avoid aiming the control at:
Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
60 ft.
(18.3 m)
The control is most sensitive to motion across it.
Least Sensitive Most Sensitive
Motion
Sensor
Motion
Clamp
Screw
Ball
Joint
Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor to aim.
Walk through the coverage
area noting where you are
when the lights turn on.
Move the sensor head up,
down, or sideways to
change the coverage area.
Set SENSITIVITY as needed.
Too much sensitivity may in-
crease false triggering.
Secure the sensor head
into position by tighten-
ing the clamp screw. Do
not overtighten the screw.
Set the amount of TIME the
lights stay on after motion is
detected. It is selectable from
1, 5, or 10 minutes.
Aim Sensor Down
for Short Coverage
Aim Sensor
Higher for Long
Coverage
Bottom of Sensor
ON-TIME
10 5 1 TEST
MIN MAX
SENS
8 ft.
(2.4 m)
Turn the SENSITIVITY (SENS) control to the mid
position and the ON-TIME control to the TEST