Heath Zenith SH-5512 Home Safety Product User Manual


 
2
598-1160-03
For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about 8 ft.
(2.4 m) above the ground. NOTE:
If fixture is mounted
higher than 8 ft. (2.4 m), aiming the sensor down will reduce
coverage distance.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and the
fixture operate at high temperatures.
• Keep fixture at least 1" (25 mm) from combustible materi-
als. Do not aim at objects closer than 3 ft. (1 m).
• Use only T3, 150W (max.) tungsten halogen 120 VAC
bulbs.
For eave mount only:
Swing the sensor head towards the clamp screw
joint.
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
Then rotate the sensor head clockwise 180° so
the controls face down.
Controls
For under eave installation, the sensor head must be
rotated as shown in the next two steps for proper operation
and to avoid the risk of electrical shock. Also for proper
under eave operation, remove the protective backing
from the light shield and stick on as shown below.
Clamp Screw
Bulb Installation and Replacement
NOTE: Bulbs are included, but you will need to install
them
NOTE: When replacing bulbs, turn power off and let
the fixture cool.
Open glass covers. To remove the old bulb push the
bulb towards the right (with fixture as shown) until
the left side of the bulb is clear of the left socket.
To install a bulb, push the bulb into the right socket
so the bulb fits completely into the left socket.
Check that the bulb is seated properly.
Close the glass covers.
Move ON-TIME Switch to
1, 5, or 20 minutes
Mode Switching Summary
Flip light switch
off for one second
then back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
INSTALLATION
CAUTION: Keep the sensor at least 1" (25 mm)
away from the bulbs.
Controls
Controls
Light Shield
Opening
DualBrite
®
Timer
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.