Wire the Light Control
For eave mount only:
Mount the Light Control
Rotate the sensor head towards the clamp screw
joint.
Then rotate the sensor head clockwise 180° so the
controls face down.
Control Switch
Joint Clamp
INSTALLATION
For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about 8 feet
(2.4 m) above the ground. NOTE:
If fixture is mounted
higher than 8 ft. (2.4 m), aiming the sensor down will reduce
coverage distance.
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
Align the light control cover plate and the junction
box holes. Secure with the mounting screws.
If not installed on a weatherproof box or if an adaptor
plate (not included) was used, caulk the wall plate
and mounting surface with silicone.
❒ Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the flood-
lamps, do not overtighten.
Keep lamps at
least 1" (25 mm)
from the sensor.
Avoid water damage and
electrical shock - keep lamp
holders below horizontal.
Lock nuts
Black to Black
White to White
Gasket
❒ Drill the holes needed
to mount the backplate
to the junction box.
❒ Remove the existing light fixture.
Route the light control’s wires through the large
gasket hole.
Connect the junction box wires to the light control
wires. Twist together and secure with a wire
connector.
WARNING: Turn power off at the fuse or circuit
breaker.
Eave Mount Wall Mount