Heath Zenith SH-5408 Home Safety Product User Manual


 
© 2008 HeathCo LLC 598-1156-03
Model SH-5408
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
• The backplate has knockouts so the sensor can be
mounted on most junction boxes.
• In some applications a universal adaptor plate may
be needed. Adaptors are available at home centers
and electrical supply stores.
Cover
Plate
Light Control
Lamp Holders
Sensor
2 Wire
Connectors
Gasket
4 Mounting
Screws (2 sizes)
This package includes:
OPERATION
* resets to Auto Mode at dawn.
TEST
10 5 1 TEST
ON-TIME
Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.
MANUAL MODE
ON-TIME
10 5 1 TEST
... back on.
AUTO
1 Second OFF
then...
Move ON-TIME Switch
to 1, 5, or 10 minutes
Mode Switching Summary
Flip light switch
off for one second
then back on*
MANUAL MODE
AUTO
TEST
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Mode: On-Time: Works: Day Night
Test
5 Sec x x
Normal
1, 5, 10 min. x
Manual
Until Dawn* x
Motion Sensor
Light Control
Meets the ENERGY STAR
®
guidelines
when used with 120 W Max bulbs.