Heath Zenith SH-5407 Home Safety Product User Manual


 
-3-
598-1155-01
Motion
Least Sensitive Most Sensitive
Sensor
Motion
The sensor is less sensitive to motion directly to-
wards it, most sensitive to motion across its fi eld
of view.
Maximum Range Maximum
Coverage Angle
8 ft.
(2.4m)
70 ft.
(21m)
RANGE
10 5 1 TEST
ON-TIME
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such
as heating vents and air conditioners. These
heat sources could cause false triggering.
• Areas where pets or traffi c may trigger the
control.
Nearby large, light-colored objects refl ecting
light may trigger the shut-off feature. Do not point
other lights at the sensor.
MAXMIN
RANGEON-TIME
10 5 1 TEST
MINUTES
MIN MAX
180°
Loosen the clamp screw
in the sensor ball joint and
gently rotate the sensor.
Walk through the cover-
age area noting where
you are when the lights
turn on (also, the LED will
ash several times when
motion is detected). Move
the sensor head up, down,
or sideways to change
the coverage area. Keep
the sensor at least 1"
(2.5 cm) away from the
lamps.
Adjust the RANGE as
needed. RANGE set too
high may increase false
triggering.
Secure the sensor head by tightening the
clamp screw. Do not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
Warning - Risk of fi re. Do not aim the lamps
at a combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . . Up to 180°
Electrical Load . . . . . . . . Up to 500 Watt (4.2A) Maximum
Incandescent [Up to 250 Watt
maximum each lamp holder.]
Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . . 1 , 5, 10 minutes
Range . . . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifi cations at any time without
incurring any obligation to incorporate new features in
products previously sold.
Turn the RANGE control to the mid position and
the ON-TIME control to the TEST position.
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage