Heath Zenith PF-4152-BK Home Safety Product User Manual


 
6
598-1166-04
TESTING
Turn on the circuit breaker and light
switch.
If you need to change the sensitivity,
temporarily remove the fixture and make
the adjustment. Too much sensitivity may
increase false triggering.
Set the amount of TIME you want the
light to stay on after motion is detected.
(1, 5, or 10 minutes).
Set the amount of time after dusk you
want the lights on accent level.
240°
Sensor Aiming
Adjustment Angle
Walk through the coverage area noting
where you are when the lights turn on.
Move the sensor head left or right to
change the coverage area.
Note: Grasp the sensor
only as shown and turn
the entire sensor. Any
other method may
damage the sensor.
Do not force it past
the stops.
Least Sensitive Most Sensitive
30 ft.
(9.1m)
Maximum Range Maximum
Coverage Angle
The detector is less sensitive to motion di-
rectly towards it and more sensitive to across
motion.
Sensor
Motion
Motion
6 ft.
(1.8 m)
Avoid aiming the control at:
Pools of water or objects that change
temperature rapidly, such as heating vents
and air conditioners. These heat sources
could cause false triggering.
• Areas where pets or traffic may trigger
the control.
Nearby large, light-colored objects reflect-
ing daylight may trigger the shut-off feature.
Do not point other lights at the sensor.
Note: Sensor has a 1
1
/
2
minute warm up pe-
riod before it will detect motion. When
first turned on wait 1
1
/
2
minutes.
150°
TEST 1 5 10 MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN
Note: Meets the ENERGY STAR
®
guidelines
when DualBrite
®
function is off.
Switch the on-time to TEST position and
DualBrite
®
switch to the OFF position.