SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 50 ft. (15.2 m); [varies with
surrounding temperature]
Sensing Angle . . . . . . . Up to 110°
Electrical Load . . . . . . . Up to 150 Watts Maximum
tungsten
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . 10 minutes
Sensitivity . . . . . . . . . . Adjustable
Replacement lamp . . . . T 150W (or less) halogen 120
VAC
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
Maximum
Range
Maximum
Coverage Angle
NOTE: Sensor requires about 1
1
/
2
minutes to calibrate
before it will detect motion. When first turned
on, wait about 1
1
/
2
minutes.
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
50 ft.
(15.2 m)
The control is most sensitive to motion across it.
Least Sensitive Most Sensitive
Motion
Sensor
Motion
Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor to aim.
Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cover-
age area. Keep the sensor at
least 1" (25 mm) away from
the lamps.
Secure the sensor head into
position by tightening the
clamp screw. Do not over-
tighten the screw.
Set the ON-TIME control to 10
minutes.
Bottom of Sensor
8 ft.
(2.4 m)
110°
Set the ON-TIME control to the TEST position.
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Clamp
Ball
Joint
ON-TIME
10 TEST