Heath Zenith 6103 Home Safety Product User Manual


 
2
598-1349-00
Typical Installation
1. Remove existing wall switch from junction
box.
2. Connect electrical leads of sensor as shown in
Figure 3. Before installing sensor into junction
box, make sure there is no wire exposed at
each connection.
3. Mount sensor into junction box using two large
mounting screws provided.
4. Turn the power back on at the circuit breaker.
5. Set mode selection switch to the AUTO posi
-
tion. When unit stabilizes (about 1 minute),
the sensor is ready to detect motion. If sensor
detects motion, the lights will turn on. The
lights will turn off 5 minutes after motion is
no longer detected.
N
O
AUTO
OF
F
AUTO
OFF ON
Green ground wire to
junction box screw or
grounding wire.
Black
Black Line
“Hot”
Neutral
Return
Lighting Load
WARNING: Turn power off at the
circuit breaker before wiring.
INSTALLING SENSOR
Removing Control Panel Cover
1. Remove the decorative cover plate (secured
by two small screws).
Mode
Selection
Switch
Figure 2 - Removing Control Panel Cover
Figure 3 - Connecting Electrical Leads of Sensor
To Lighting Load