Heath Zenith 598-1165-03 Home Safety Product User Manual


 
5
598-1165-03
TESTING
Turn on the circuit breaker and light
switch.
Set the SENSITIVITY as needed. Too much
sensitivity may increase false triggering.
Set the amount of TIME you want the light
to stay on after motion is detected. (1, 5,
or 10 minutes).
240°
Sensor Aiming
Adjustment Angle
SPECIFICATIONS
Range . . . . . . . . . . Up to 30 ft. (9.1 m)
[varies with surrounding
temperature].
Sensing Angle . . . . Up to 150°, 240°
adjustable
Electrical Load . . . . Up to 100 Watt Maximum
Incandescent
Sensor Capacity . . Up to 500 Watt (4.1 A.)
Maximum
Power Requirements .... 120 VAC, 60 Hz
Operating Modes . . TEST, AUTO, and
MANUAL MODE
Time Delay . . . . . . 1, 5, 10 minutes
DESA Specialty Products reserves the right to
discontinue products and to change specifica-
tions at any time without incurring any obliga-
tion to incorporate new features in products
previously sold.
Walk through the coverage area noting
where you are when the lights turn on.
Move the sensor head left or right to
change the coverage area.
Note: Grasp the sensor
only as shown and turn
the entire sensor. Any
other method may
damage the sensor.
Do not force it past
the stops.
Least Sensitive Most Sensitive
30 ft.
(9.1m)
Maximum Range Maximum
Coverage Angle
The detector is less sensitive to motion directly to-
wards it and more sensitive to across motion.
Sensor
Motion
Motion
6 ft.
(1.8 m)
Avoid aiming the control at:
Pools of water or objects that change
temperature rapidly, such as heating vents
and air conditioners. These heat sources
could cause false triggering.
• Areas where pets or traffic may trigger
the control.
Nearby large, light-colored objects reflect-
ing daylight may trigger the shut-off feature.
Do not point other lights at the sensor.
Note: Sensor has a 1
1
/
2
minute warm up pe-
riod before it will detect motion. When
first turned on wait 1
1
/
2
minutes.
TEST 1 5 10 MIN
ON-TIME
LO - M - HI
SENSITIVITY
150°
Turn SENSITIVITY to mid position and
ON-TIME to TEST position.