Heath Zenith 5716 Home Safety Product User Manual


 
3
598-1307-01
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost. [varies
with surrounding temperature]
Sensing Angle . . . . . . Up to 270°
Electrical Load . . . . . . Up to 300 Watts Maximum Incan-
descent
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Lamp Modes . . . . . . . Normal, Soft, Flash
Time Delay . . . . . . . . 1, 5, 20 minutes
DualBrite
®
Timer . . . . Off, 3, 6 hours, Dusk-to-Dawn
HeathCo LLC reserves the right to discontinue products
and to change specifications at any time without incurring
any obligation to incorporate new features in products
previously sold.
Motion
Motion
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
1
/
2
minute warm up period before
it will detect motion. When first turned on or when
switching modes wait 1
1
/
2
minutes.
Bottom of Sensor
Avoid aiming the sensor at:
• Objects that change temperature rapidly, such as heat-
ing vents and air conditioners. These heat sources
could cause false triggering.
• Areas where pets or unwanted traffic may trigger the
control.
Nearby large, light-colored objects reflecting light may
trigger the shut-off feature. Do not point other lights at
the sensor.
8 ft.
(2.4 m)
70 ft. 100 ft.
(21 m) (30.5 m)
Boosted
Least Sensitive Most Sensitive
Sensor
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
270°
Turn the RANGE control to the medium position
(halfway between MIN and MAX), DualBrite
®
to OFF,
and the ON-TIME control to the TEST position.
Loosen the clamp screw in the
sensor ball joint and gently rotate
the sensor.
Walk through the coverage area
noting where you are when the
lights turn on. Move the sensor
head up, down, or sideways to
change the coverage area. Keep
the sensor at least 1" (2.5 cm)
away from the lamps.
Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
Secure the sensor head's aim
by tightening the clamp screw.
Do not overtighten the screw.
Set the amount of TIME you want
the lights to stay on after motion is
detected (1, 5, or 20 minutes).
Set the DualBrite
®
switch to the amount of time after
dusk you want the lights on at low level (Off, 3, 6 Hrs.,
Dusk-to-Dawn).
Set the LAMP MODE switch to the desired light turn-
on effect (Normal, Soft, Flash).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Maximum Range Maximum
Coverage Angle
LAMP MODE
NORMAL SOFT FLASH
ON-TIME DUAL BRITE™
TEST 1 5 20
MINUTES
OFF 3 6 DUSK TO
HOUR DAWN
MAXMIN
RANGE