Heath Zenith 5212 Home Safety Product User Manual


 
3
595-5734-04
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 60' (18m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . Up to 110°
Electrical Load . . . . . . . Up to 150 Watts Maximum (per
adapter) Incandescent.
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . 1 , 5, 10 minutes
Sensitivity . . . . . . . . . . Adjustable
DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.
The detector is less sensitive to motion directly towards
it and more sensitive to cross motion.
Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cover-
age area.
Adjust the SENSITIVITY as
needed. Too much sensitivity
may increase false triggering.
Set the amount of TIME you
want the lights to stay on after
motion is detected (1, 5, or 10
minutes).
Least Sensitive Most Sensitive
Sensor
Motion
Motion
ON-TIME
10 5 1 TEST
MIN MAX
SENS
Bottom of Sensor
60 ft.
(18m)
5 to 9'
(1.5-2.7 m)
Maximum Range Maximum
Coverage Angle
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
110°
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
Turn the SENSITIVITY (SENS) control to the mid
position and the ON-TIME control to the TEST
position.
NOTE: Sensor has a 1
1
/
2
minute warm up period
before it will detect motion. When first turned
on or when switching from Manual to Auto
mode wait 1
1
/
2
minutes.