Heath Zenith 3035698 (AC-6190) Door User Manual


 
-3-
598-1077-02
Code and Tune Settings
Code Settings
Note: Most installations will not require you to change any
jumpers on your chime and push button.
WARNING: Disconnect chime unit from power source before
opening code access door. Close door and replace screw
before reconnecting to power.
The push button and chime communicate by using a code that
can be changed by removing and/or adding jumpers on both the
push button and chime. The code is factory set; however, there
are 128 selectable codes that allow you to expand your system
and prevent outside interference. Other wireless products may
cause interference and the system may not function properly.
Follow the instructions below for setting a new code.
1. Unplug wireless chime (if applicable).
2. Open the cases and locate the jumpers on both the push button
and chime (See illustration on page 5).
3. The push button and chime both have eight different jumper
locations. The jumper positions 1 through 7 are used for setting
the code.
4. To change the code, add and/or remove jumpers as needed. It
is recommended to only change one jumper at a time and then
check to see if system is functioning properly. Note: Jumpers
in positions 1 through 7 must be exactly the same for both the
push button and chime for this system to function.