4
598-1325-00
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
MAX
MIN
RANGE
ON-TIME
DUAL BRITE™
TEST 1 5 20
MINUTES
OFF
3
6
DUSK TO
DAWN HOUR
B
O
O
S
T
TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
1
/
2
minute warm up period
before it will detect motion. When first turned
on, wait 1
1
/
2
minutes.
❒ Turn the RANGE control to the medium position
(halfway between MIN and MAX), DualBrite
®
to OFF,
and the ON-TIME control to the TEST position.
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several
times when motion is detect-
ed). Move the sensor head up,
down, or sideways to change
the coverage area. Keep the
sensor at least 2" (51 mm)
away from the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head
by tightening the clamp
screw. Do not overtighten the
screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
❒ Set the DualBrite
®
switch to the amount of time after
dusk you want the lights on at low level (Off, 3, 6
Hrs., Dusk-to-Dawn).
WARNING - Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
Maximum
Maximum Range Coverage Angle
15 ft.
(4.6 m)
70 ft. 100 ft.
(21 m) (30.5 m)
Boosted
240°
DualZone™
DualZone™
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Motion
Motion
Sensor
DualZone™DualZone™
NOTE: DualZone™ adds a zone of detection under
the motion sensor. DualZone™ requires no additional
adjustment and operates in conjuction with the for-
ward-looking sensor.
Least Sensitive Most Sensitive
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.