Heatcraft Refrigeration Products TA Fan User Manual


 
9
Nomenclature
RAM K 13 A G
Voltage
A = 115/1/60
B = 208-230/1/60
Reverse Air Flow
Kompact Mullion
Size
Bohn-Kote® Coil
Vintage
Features
• Textured aluminum cabinet
PVC coated fan guard
Stainless steel hardware
Coils have full collar aluminum ns on expanded
copper tubes
Bohn-Kote® coated coil for optimum protection in
corrosive environments
Refrigerant connection knockouts provided on both
ends of unit
Expansion valve mounts inside the unit
Motors are thermally protected and
permanently lubricated
Internal junction box for electrical connection
Adjustable air deector included provides dierent
air patterns. Air can be directed where its needed
All models are UL listed for the US and Canada
UL classied to NSF standards
Sweat inlet connection to reduce leaks
(are connection available as a ship loose option)
Application
Model RAMK is ideal for under-counter reach-in refrigerators,
under-counter drawer type refrigerators and salad bars. The
unit is suitable for mounting behind a mullion or on a wall. An
up ow air pattern is used with air drawn in at the bottom and
discharged out the top. This provides optimum temperature for
drop in trays on salad bars or prep tables. It also keep drawer
stored product in premium condition.
An adjustable and detachable air deector/splash protector
is included. The deector can be adjusted to direct the air up
and out at a 45-degree angle. This feature provides excellent
air distribution over drop in trays or containers. Food in the
trays and containers stays colder, lasts longer, and retains the
desired appearance. The deector can be adjusted to distribute
air out both sides when used as a mullion unit.
Exclusive Bohn-Kote® Finish is Standard
The nned coil is protected by Bohn-Kote® - a special dip coating
that is baked on to prevent corrosion of the coil by acids that
are present in salad dressings, spiced meats and other food
products.
Model RAMK
Reverse Air Flow Kompact Mullion Reach-In Unit Cooler
Table 13. Performance and Electrical Data
Diagram 7. Dimensions
Table 14. Physical Data
Model
BTUH
10°F
TD
Motor Data Connections (in.) Approx.
Ship Wt.
(lbs.)
CFM Qty.
115/1/60
Total FLA
208-230/1/60
Total FLA
Coil Inlet
OD
Suction
ID
Drain
OD
RAMK13 1,300 180 2 1.6 0.8 3/8 3/8 5/8 19
RAMK17 1,700 170 2 1.6 0.8 3/8 3/8 5/8 20
RAMK23 2,300 255 3 2.4 1.2 3/8 1/2 5/8 28
Model
Dimensions (in.)
H L M W X Y Z
RAMK13 17-3/4 16-7/8 9 15-5/8 2-3/4 5-1/2 6-15/16
RAMK17 19-3/4 16-7/8 10 15-5/8 2-3/4 6-1/2 7-15/16
RAMK23 19-3/4 23-1/4 10 22 2-5/16 6-1/2 7-15/16