Heat & Glo • Supreme-XTS, Grand-XTS • 349-901 Rev. i • 12/09
CAUTION
ALL vent speci cations MUST be followed.
This product is tested and listed to these speci cations.
Appliance performance will suffer if speci cations are not
followed.
EXHAUST VENT PIPE
TERMINATION CAP
ADAPTOR
INSULATION SEAL
INLET VENT AIR PIPE
Figure 5.1
C. Measuring Standards
Vertical measurements listed in the vent diagram (Figure
5.1) were made using the following standard:
• Vertical terminations are measured to top of chimney.
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a
chimney ue serving a separate solid fuel or
gas burning appliance.
May impair safe operation of this appliance
or other appliances connected to the ue.
Vent this appliance directly outside.
Use separate vent system for this appliance.
B. Horizontal Venting
Horizontal venting is NOT allowed.
5
5
Vent Information and Diagrams
A. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
Symbol Description
V
MIN
Minimum Vertical Run Length 14 ft.
V
MIN
Maximum Vertical Run Length 50 ft.
WARNING