Heat & Glo LifeStyle SLR-B (COSMO) Indoor Fireplace User Manual


 
Heat & Glo • SLR-B • 2195-900 Rev. P • 12/11 25
Figure 7.4
Top Vent - Horizontal Termination
Venting with 1 elbow
H
1
V
1
V Minimum
H
1
Maximum
SLR-B
90 Elbow 1-1/2 ft. 457 mm
1 ft. 305 mm 3 ft. 914 mm
2 ft. 610 mm 5 ft. 1.5 m
3 ft. 914 mm 7 ft. 2.1 m
4 ft. 1.2 m 14 ft. 4.3 m
H MAX. =14 ft. (4.3 m)
V + H MAX. = 40 ft. (12.2 m)
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling fi restops.
ALWAYS maintain specifi ed clearances around venting and fi restop systems.
Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.
WARNING
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).
CAUTION: The SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps are not approved for use with pro-
pane (LP) fuel. May lead to elevated glass temper-
ature that may cause tempered glass breakage.