Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/0716
A. Installing Outside Air Kit Damper Assembly
Appliance Preparation
7
CAUTION
Sharp Edges
• Wear protective gloves
and safety glasses dur-
ing installation.
Asphyxiation Risk.
Fire Risk.
Do NOT draw outside combustion air from:
• Wall, fl oor or ceiling cavity.
• Enclosed space such as an attic or garage.
• Close proximity to exhaust vents or chimneys.
Fumes or odor may result.
• Remove and discard cover plate or knockout from side
of appliance.
• Open air kit damper slightly.
• Locate door hinge toward back of appliance (see Figure
7.1).
• Attach damper assembly to appliance using screws
provided (see Figure 7.2).
• Insert narrow end of handle through tab and into upper
slot of door.
• Check handle operation. Pull handle out to open, and in
to close.
Figure 7.2 Outside Air Kit Installation
Figure 7.1 Damper Assembly and Handle
HANDLE
HING
E
D
OO
R
B. Gas and Electrical Connections
If applicable, ensure that gas and electrical connections are
installed at this time. Refer to Sections 9 (Gas Information)
and 10 (Electrical Information).
WARNING