C. Sidewalls/Surrounds
Adjacent combustible side walls must be located a minimum of 24 in. (610 mm) from the replace opening. See Figure 3.3.
If you are using a decorative surround constructed of combustible material, it must be located within the shaded area de-
ned in Figure 3.3. Short stub walls are also acceptable if they are contained within the shaded area.
D. Frame the Fireplace
Figure 3.4 shows a typical framing (using 2 x 4 lumber) of the replace, assuming combustible materials are used. All re-
quired clearances to combustibles around the replace must be adhered to. See Figure 3.2. Any framing across the top of
the replace must be above the level of the top standoffs.
23-3/4 in.
(603 mm)
50°
42 in.
(1067 mm)
51-1/2 in.
(1308 mm)
39°
4 in.
(102 mm)
BRICK
FRONT
FLUSH FRONT
24 in.
(610 mm)
19-3/4 in.
(502 mm)
24 in.
(610 mm)
Figure 3.3 Sidewalls and Surrounds
Note: Fireplace header
cannot be positioned until
after the fireplace
assembly is in place.
Use only noncombustible
material below the top of
the front standoffs.
2 in. (51 mm)
minimum air
space clearance
to the enclosure.
28-1/2 in.
(724 mm)
51-1/2 in.
(1308 mm)
Figure 3.4 Framing the Fireplace
¨