Heat & Glo LifeStyle EM-485TH Indoor Fireplace User Manual


 
34
European Copper Series Termination Cap
Heat & Glo • EM-415, EM-485 • 33056 • Rev V • 05/08
Chimney
Pipe
Chase Top
Termination Cap
Chase
3 in. (76 mm)
Maximum
top of chase to
top of
chimney section
Collar
2 in. (51 mm)
Minimum Height
Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm).
Place waterproof
sealer under each
flange of the termina-
tion cap and on top of
each screw to help
prevent leaks.
Figure 9.7 Installing a TS345/TS345P Square Termination Cap
TS345/TS345P Square Termination Cap
Chimney
Pipe
Chase Top
Termination Cap
Chase
Collar
2 in. (51 mm)
Minimum Height
Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)
Place waterproof
sealer under each
flange of the termina-
tion cap and on top of
each screw to help
prevent leaks.
The last section of pipe
must stop between 2 in.
(51 mm) above top of
chase and 7 in. (178
mm) below top of chase
2 in. (51 mm)
7 in. (178 mm)
Figure 9.8 Installing a TCT375 Terra Cotta Cap
TCT375 Terra Cotta Cap
European Copper Series Termination Cap
brass screw (8)
(9 for the King-Style)
bolt (8)*
Cap Top
Cap Base
(Be sure holes
in cap top and
cap base are
aligned.)
Cap top comes assembled in place.
bracket (8)*
washer (8)*
nut (8)*
CT-3A
Adapter
2 in. (51 mm)
typical collar height
chase
top
(metal or masonry)
screw (8)*
SL pipe
14-1/2 in.
(368 mm)
Figure 9.9 Installing an Adapter for European Copper Cap Se-
ries (CT-King shown)