Heat & Glo LifeStyle CFL-30LP-B Indoor Fireplace User Manual


 
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
19
1. "STOP!" Read the safety information on previous
page.
2. Open the control access cover (logs #3 and 4 in
CFL models) or (logs #4 and 5 in ST-CFL
model), refer to your Log Placement Instructions.
3. Turn the valve control knob to the "OFF"
position. To do this, you must turn the knob
clockwise to the "Pilot" position, and
then press in and continue turning
clockwise to the "OFF" position.
GAS CONTROL VALVE
NOTE: Knob cannot be turned from "PILOT" to
"OFF" unless knob is pushed in slightly. Do not
force.
4. WAIT FIVE (5) MINUTES TO CLEAR OUT
ANY GAS. Then smell for gas, including near
the floor. If you then smell gas, STOP! Follow
"B" in the safety information previous page. If
you don't smell gas, go to the next step.
5. The pilot should not require accessing for
lighting purposes. The pilot is located at the
end of the burner.
THERMOPILE PILOT BURNER
6. To put the control in the "Pilot" position, turn the
control knob counter-clockwise
to the
"Pilot" position.
7. To light the pilot depress the control knob and then
depress the red piezo button until it makes a
clicking sound. It may be necessary to repeat this
step. If the pilot does not light after 10 seconds, go
back to step 3. The control knob should be held
down for a MINUTE after pilot ignition.
If the control knob does not pop out when
released, STOP-shut off the gas supply to
the fireplace control valve, and IMMEDI-
ATELY call your service technician or gas
supplier.
If the pilot will not stay lit after two tries, turn
the control knob to the "OFF" position and
call your service technician or gas supplier.
8. After the pilot has been lit, the burner can be turned
on by turning the knob counter-clockwise
to the "ON" position. Flip the ON/OFF
switch to the "ON" position. (This is located to the
right on the burner leg and behind the control
access cover.)
9. Close control access cover.
1. Turn ON/OFF switch to "OFF".
2. Open the control access cover.
3. Turn the valve control knob clockwise
to the "Pilot" position, then depress knob and
continue turning to "OFF" position.
4. Close control access cover.
TO TURN OFF GAS APPLIANCE
LIGHTING INSTRUCTIONS
LIGHTING INSTRUCTIONS