Heat & Glo LifeStyle 8000TVLP-OAKIPI Gas Heater User Manual


 
10 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08
CLEARANCES TO COMBUSTIBLES
ABCD E F G H I J
Rough
Opening
(Vent Pipe)
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Behind
Appliance
Sides of
Appliance
Front of
Appliance
Inches
10 40-1/2 22 49 32 0 0 1/2 1/2 36
mm
254 1029 559 1245 813 0 0 13 13 914
Fire Risk.
Construct chase to all clearance speci cations
in manual.
• Locate and install appliance to all clearance
speci cations in manual.
B. Constructing the Appliance Chase
A chase is a vertical boxlike structure built to enclose the
gas appliance and/or its vent system. Vertical vents that
run on the outside of a building may be, but are not re-
quired to be, installed inside a chase.
Construction of the chase may vary with the type of build-
ing. These instructions are not substitutes for the require-
ments of local building codes. Local building codes MUST
be checked.
Chases should be constructed in the manner of all out-
side walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.
Walls, ceiling, base plate and cantilever oor of the chase
should be insulated. Vapor and air in ltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air in ltration may be an issue, the inside surfaces may be
sheetrocked and taped for maximum air tightness.
To further prevent drafts, the wall shield and ceiling re-
stops should be caulked with high temperature caulk to
seal gaps. Gas line holes and other openings should be
caulked with high temp caulk or stuffed with unfaced insu-
lation. If the appliance is being installed on a cement slab,
a layer of plywood may be placed underneath to prevent
conducting cold up into the room.
C. Clearances
Figure 3.2 Clearances to Combustibles
Fire Risk.
Odor Risk.
Install appliance on hard metal or wood surfaces
extending full width and depth of appliance.
Do NOT install appliance directly on carpeting,
vinyl, tile or any combustible material other than
wood.
Do NOT place furniture or any other combustible
household objects within 36 inches of the
appliance front.
C
B
D
A
J
I
H
E
F
TOP OF
HOOD
TO
CEILING
G
WARNING
WARNING